User's Manual

Parameter
Description
Period
Configure working period, and the rule takes effect only within this period.
1. Click Setting to open the Period setting window.
2. Configure each period.
A: Press and hold the left mouse button, and then drag at the periods you
need.
B: Click the Setting behind the week day you need, and then the week day
in the period setting box shows red color, select and configure the
periods you need, and you can configure 6 periods in one week day at
most.
3. Click OK.
Duration
Set the amount of time, in seconds, that targets must remain in the defined
area before the function triggers the alarm.
Set the time between 10 seconds and 300 seconds (default: 10 seconds).
Sensitivity
Set the sensitivity level for the speed of the object entering and exiting the
designated area.
Set the sensitivity between 1 and 10 (default: 5).
Record
Select Record to send video data to the camera’s onboard storage when a
tripwire alarm is triggered. Then, set a record delay period, in seconds.
The camera must have an on-board storage mechanism, specifically a
MicroSD card slot with a MicroSD card installed.
Relay Out
Select Relay-out to send an alarm transmission signal from the camera to
an alarm relay. Then, set an Alarm Delay period, in seconds.
The camera must have an active alarm relay connection.
Send Email
Select Send Email to issue an email when an alarm is triggered. Set email
addresses in the Network -> SMTP (email) setting box.
Snapshot
Select Snapshot to record a snapshot of the scene that shows the tripwire
violation.