User's Manual
The settings are as follows:
6.
UTC Function
Access the Setting function and select “SD-UTC” protocol.
Press key to switch "TVI", key to switch "AHD", the key to switch "SD", and the key to switch
"CVI". Select the protocol "UTC-B" when the speed dome uses this feature.
Attention: This function supports switching from SD mode to HD mode. Please use OSD to switch before
HD mode.
Automatic shut-down Time Setting
Choose the Automatic shut-down function, press button to adjust the options.
Adjust the step length to 5 Min. Minimum 5 Min, Maximum 60 min. Select disable to turn off automatic
shutdown.
Tester will be power-off when it’s idled to the setting time.
Setting Keyboard Sound Prompts
Choose the keyboard sound function to turn keyboard sounds on or off.
Modify Back-light Brightness
Choose back-light brightness function to adjust screen back-light brightness.
The tester display screen back-light brightness has 10 levels of adjustment and increases screen
brightness in outdoor environments with a bright light.
System Upgrade
1. Place the tester into burning mode.
2.Connect the USB end to the tester.
3.Connect the other end of the USB cable to the computer.
4.Press the light button next to the power button. Then, press the power button and the light button for
3 seconds at the same time. The device enters the burning mode.
5.Use zadig-2.3 to install the USB driver of the corresponding device
6.Click on the computer to run zadig-2.3 software.
8.Click the Install Driver button to install the corresponding driver.
9. Click on the Upgrade Tool 1.0.exe to run the software.
10. Click the Acquisiton Device button on the left to get the device USB information in the list.
Analog Audio Test
The tester is equipped with an audio function to test microphones or other audio devices. After the
connection is established, the tester broadcasts sound from the device via the built-in speaker.
Attertion: Use the 3.5 mm audio cable that shipped wiht the tester to connect audio device. The Black
clamp is earth connection, the red clamp is signal connection.
Please connect earth first to avoid a loud noise during connection.
System Setting
Use the System settings function to access the Operating parameters.
Press button to choose “settings” function, press button and access into “settings” interface.
5. RS485 PTZ Control
Enter the setting interface to set relevant RS485 parameters. After setting, RS485 control can be carried
out on the camera.
After setting, press the key to exit. Settings are applied immediately.
After the setting is vaild, used key and Directional key to control the PTZ.
Use supplementary RS485 power cable to connect to the PTZ RS485 communication lines.
Use and Directional key to control PTZ turn up.
76 8 9 10 11
Select Coaxial PTZ protocol
CVI protocol(dahua coax)
AHD protocol(Pelco c)
TVI protocol(Hikvision)
Protocol
Baud Rate
Address
Speed
Set Preset
Go Preset
Not Necessary for Coaxial Control
Expected PTZ speed, range from 1~63.
Camera’s current position to its internal storage.This function is provided by the camera.
Refer to the camera manual.
The camera moves to the corresponding pre-saved position at maximum speed. This
function is provided by the camera, please refer to the camera manual.
Address of PTZ to control. Due to different camera manufacturer setting, the address may
offset by +/- 1. Address range depends on the protocol.
Select RS485 PTZ protocol.
The tester supports many PTZ protocols.
Protocol
Baud Rate
Address
Speed
Set Preset
Go Preset
RS485 communication baud rate.
Expected PTZ speed, range from 1~63.
Camera’s current position to its internal storage.This function is provided by the camera.
Refer to the camera manual.
The camera moves to the corresponding pre-saved position at maximum speed. This
function is provided by the camera, please refer to the camera manual.
Address of PTZ to control. Due to different camera manufacturer setting, the address may
offset by +/- 1. Address range is depend on the protocol. Coaxtron no need to set up.
The settings are as follows:
SCR
Use button to choose the needed options or the needed functions.
After modifying the settings, press to save up the setting.
11. Click the file Select File button on the right. In the pop-up selection folder, select the bin file you
want to burn.
12. Disconnect the USB connection between the burning device and the computer, and exit the
burning mode.
13. Press the power button to restart the device to view the burned information.
2. Analog Video Test
3. Camera OSD menu
Enter the setting interface to set the protocols used by the analog camera, such as CVI protocol
(dahua coax), AHD protocol (Pelco c) and TVI protocol (Hikvision) or choose an adaptive coax
protocol.
After entering the analog video interface, press OK to call up the OSD menu for the analogcamera,
then select the desired camera function.
For an analog PTZ camera, enter the setting interface, select "PTZ camera Control" - OSD Control,
click OK to call up the OSD menu of PTZ camera.
4. HD Coaxial PTZ Control
Enter the setting interface to set the corresponding control protocol and relevant parameters. After
setting, the camera can be controlled.
1. Connect the camera to the tester with the coax cable.
2. Select Analog video from the main interface or press key to select Analog video from the menu,
and then enter the camera test interface for testing.
6
SCR
7.Click on Options in the menu bar, Select List All Devices, then select the USB
of the corresponding device in the list below.