User's Manual
Table Of Contents
- Foreword
- Important Safeguards and Warnings
- 1 Overview
- 2 Configuration Flow
- 3 Device Initialization
- 4 Login
- 5 Main Interface
- 6 Setting
- 6.1 Local
- 6.2 Camera
- 6.2.1 Setting Image Parameters
- 6.2.2 Setting Encode Parameters
- 6.2.2.1 Encode
- 6.2.2.2 Overlay
- 6.2.2.2.1 Configuring Privacy Masking
- 6.2.2.2.2 Configuring Channel Title
- 6.2.2.2.3 Configuring Time Title
- 6.2.2.2.4 Configuring Location
- 6.2.2.2.5 Configuring Font Properties
- 6.2.2.2.6 Configuring Picture Overlay
- 6.2.2.2.7 Configuring Custom Title
- 6.2.2.2.8 Configuring Target Statistics
- 6.2.2.2.9 Configuring Face Detection
- 6.2.2.2.10 Configuring Face Recognition
- 6.2.2.2.11 Configuring Face Statistics
- 6.2.2.3 ROI
- 6.2.3 Setting Audio Parameters
- 6.3 Network
- 6.4 Event
- 6.5 Storage
- 6.6 System
- 6.7 System Information
- 6.8 Setting Log
- 7 Live
- 8 AI
- 9 Camera
- 10 Event
- 11 System
- 12 Security
- 13 Record
- 14 Picture
- 15 Report
- Appendix 1 Cybersecurity Recommendations
Operation Manual
86
8.1.2 Rule Configuration
When the number of people or the crowd density in the detection area exceeds the configured
threshold, the system performs alarm linkages.
Prerequisites
● Select
AI
>
Smart Plan
, and enable
Crowd Distribution Map
.
● You have configured the parameters on the
Global Config
interface.
Procedure
Step 1 Select
AI
>
Smart Plan
Step 2 Click next to
Crowd Distribution Map
, and then click
Next
.
Step 3 Click the
Rule Config
tab.
Figure 8-2 Rule configuration
Step 4 Click next to
Enable
, and then the crowd map function is enabled, and the
detection area box is displayed on the image.
Click , and you drag the any corner of the box to adjust the size of the area, and
press the left mouse button and move the box to adjust the position.
Step 5 Draw multiple people counting areas in
Detection Area
as needed.
1) Click
Add Rule
to add statistical areas.
2) Set the name of
Area
and
People Number to Trigger Alarm
.
When the number of the people in the area exceeds the configured threshold, the
alarm will be triggered, and the system will perform the linkage actions. The people
number to trigger alarm is 20 by default.
3) Click at the right side of the image, draw people counting areas in the
detection area, and then right-click to finish the drawing.
4) Repeat the above steps to add more people counting areas.
● Click , and then press and hold the left mouse button to draw a rectangle,
and then pixel size is displayed.
● Click to delete the drawn detection or people counting areas.
Step 6 Configure parameters.
Table 8-1 Description of crowd map parameters
Parameter
Description
Global
Click next to
Global
and set the crowd density threshold.