Parameter
Description
Flowrate Alarm
Set Enter No., Leave No., and Stranded No. The alarm is triggered
when the configured value is reached.
Regional People
Number
Statistics Alarm
Set the number of people in the people counting region. When the
people count reaches the threshold or the stay duration exceeds the
configured value, the alarm is triggered.
When you set inside number to be 0, and select the type to be
Thredhold, the system will not perform the alarm linkage.
Inside Number
Type
Stranding Alarm
Select the Stranding Alarm check box, and then set the stranding time,
when the stay duration exceeds the configured value, the alarm will be
triggered.
Stranding Time
Sensitivity
Set the alarm-triggered sensitivity. The higher the sensitivity is, the
easier the alarm will be triggered.
Set arming periods and alarm linkage actions. For details, see "5.1.1 Alarm Linkage." Step 6
Click Save. Step 7
To view alarm information on the Alarm tab, subscribe relevant alarm event. For details,
see "5.1.2 Subscribing Alarm."
Verification
You can view the counting result on the Live interface. See Figure 5-54.
For People Counting rule, the entry and exit numbers are displayed.
For In Area No. rule, the inside number is displayed.
Counting result Figure 5-54