5.5 Triggering&synchronization
In case multiple systems are used during a measurement it is important to have the measurement data
synchronizedbetweenthesystems.Processingsynchroniseddataismucheasierbecausethereisnoneedto
resamplethedatatocompensatefortiminginaccuracieslikeclockdriftandclockdeviations.Synchronization
usingmultiplesystemsinvolves2importantissues:startingthemeasurementatthesametimeandhavinga
fixedtimerelationshipofthesamplinginstances.ThissectionwillexplainhowtheMTi/MTxmustbesetup
whenusingmultiplemeasurementsystems.
The MTi / MTx have capabilities to be triggered by external devices or trigger external devices. These two
scenariosareexplainedinthefollowingsubsections.
5.5.1 ExternaldevicetriggersMTi/MTx
In the following figure, a possible configuration is shown where a Motion Tracker and Device A are
synchronised. In this example, a clock generator triggers device A and a MTi / MTx ensuring that the two
devicesaresynchronizedwitheachother.
TheoutputoftheclockgeneratorcanbedirectlyconnectedtotheMTi/MTxortothespareheaderofthe
USBconverterasshowninthefigureabove.Moreinformationaboutthiscanbefoundinsection6.4.1.
NOTE:AlwayscheckiftheSyncInspecificationmatcheswiththetriggersignal.Seesection6.4.
The following MTi / MTx devicessupport SyncIn, MTi28A##G## (MTi RS232), MTi48A##G## (MTi RS485),
MTi68A##G##(MTiRS422)andMTx28A##G##(MTxRS232).
TheSyncInsignalcaneithertriggerthetransmissionofthelatestdataortheinternalsensorsampling.Thefirst
SyncInmodeishighlyrecommendedinsituationswheretheclocksignalisnotreliableand/oraccurate.More
informationisgiveninthenexttwosections.FormoreinformationabouttheSyncInmodesandsettingssee
MTiandMTxLowLevelCommunicationDocument.
Transmissionofthelatestdata
InthisSyncInmodetheinternalclockand thestoredsamplefrequencydeterminewhenthesamplingofthe
sensorsignalsstart.ThedataistransmittedonlyifatriggerisdetectedontheSyncInline.Thismeansthatthe
triggerinstance will not coincide with the sampling instanceof the transmitted data. Because twodifferent
clocks are used the time difference between the trigger instance and the sampling instance may also vary
duringthemeasurementandatmostwithatimeequaltotheusedsamplingperiod.Neverthelessthismodeis
preferred if the clock generatoris not that accurate as the internal clock of the MTi / MTx. In this mode a
SyncIntriggerwillalwaystransmitthelatestdataavailable.
MT
USB
Converter
Device A
S
y
ncIn
Clock
generator
Trigger in