Technical data

Fitted Equipment
83
Failure : The refrigerator does not cool sufficiently
Possible cause Action you can take
Inadequate ventilation to the unit.
The thermostat setting is too low.
There is too much ice on the condenser.
Too much warm food put inside.
Appliance running for a short time.
Check that the ventilation grilles are not
covered.
Turn the thermostat to a higher setting.
Check that the refrigerator door seals
when shut.
Let food cool down first.
Wait several hours, check again.
MAINTENANCE
Works on gas components and electrical
installation may only be carried out by
authorised personnel. We recommend
you contact your Dometic Service Centre.
EN 1949 stipulates that the appliance´s
gas equipment and it’s associated fume
system must be inspected after
installation and a certificate issued.
Afterwards a qualified technician must
inspect according to EN 1949 every two
years and a certificate issued.
It is the user’s responsibly to arrange
for inspections after purchase.
It is recommended that the gas burner be
inspected and cleaned as necessary at
least once a year.
We recommend maintenance following an
extended shutdown of the vehicle.
PRODUCT LIABILITY
Product liability of Dometic GmbH does not
include damages which may arise from
faulty operation, improper alterations or
intervention in the equipment, adverse
effects from the environment such as
changes in temperature and air humidity,
which may impact the equipment itself or the
direct vicinity of the equipment or persons in
the area.
ENVIRONMENTAL HINTS
Refrigerators manufactured by Dometic
GmbH are CFC-free.
Ammonia (a natural compound of hydrogen
and nitrogen) is used in the cooling unit as a
coolant. The non-ozone-hazardous
cyclopentan is used as a propellant in the
manufacture of the PU foam insulation.
DISPOSAL
In order to ensure that the recyclable
packaging materials are re-used, these
should be sent to the usual local collection
system.
The appliance should be transferred to a
suitable waste disposal company that will
ensure re-use of the recyclable components
and proper disposal of the rest.
For eco-friendly draining of the coolant from
all absorber refrigeration units, a suitable
disposal plant should be used.
ENERGY-SAVING TIPS
At an average ambient temperature of
approx. 25°C, it is sufficient to operate the
refrigerator at the middle thermostat
setting (for both gas and mains voltage).
Where possible, always store goods that
have previously been cooled.
Do not position the refrigerator in direct
sunlight.
Constant circulation of air must be
supplied to the refrigerator unit.
Defrost regularly.
Open the door only for a short time when
removing goods from the refrigerator.
Run the refrigerator for about 12 hours
before filling it.