Technical data
Fitted Equipment
1. Set energy selector switch (A) to gas
2. Set rotary switch (B) to "MAX" position.
The ignition process is activated
automatically, accompanied by a ticking
sound approx. 30 sec. Upon successful
ignition, the display LED (C) "Gas" lights
yellow.The refrigerator is in function. Use
rotary switch (B) to regulate the temperature
in the main refrigerator compartment.
GAS FAULTS
In the event of a gas fault (e.g. gas cylinder
empty), the operating display (C) flashes
yellow.
Remedies:
Set the energy selector switch (A) to
position "OFF".
1. Is there any gas in the gas bottle?
2. Is the gas bottle valve open?
3. Is the on-board shut-off valve open?
4. Set the main switch (A) to "on"
The reignition starts again.
If after about 30 seconds the operating
display (C) starts flashing red again, the
gas fault has not been cleared (e.g. air in
the gas pipe).
5. Briefly switch the refrigerator off and then
on again using main switch (A).
To remove air from the gas pipes, repeat
this procedure 3-4 times.
If these actions do not help, please call an
authorised Dometic Service Centre.
AUTOMATIC ENERGY SELECTION (ONLY
WITH RM 7XX5 L)
"AUTO"-OPERATION
RM7XX5 L - models are equipped with an
"AUTO"-MATIC function.
1. Set energy selection switch (A) to position
"AUTO" .
The LED "AUTO" illuminates.
Note: Manual operation is possible at any
time.
Explanations
Upon switching on, the electronics
automatically select one of the three
possible energy types: 230V - 12V - liquid
gas. The control electronics
automatically ensure that the refrigerator is
supplied with the optimum source of energy
in each respective case.
Priority 1.) Solar (12V DC)
2.) 230V AC
3.) 12V DC
4.) Liquid gas
The selected energy is displayed by the
corresponding LED (i.e. 230V).
230 V - operation
If sufficient supply voltage is available (more
than 200V), this power source is selected as
the first option ( no solar-system installed).
12 V - operation
12V operation should only be selected while
the vehicle motor is running or there is
sufficient voltage available from the solar
76