ALDE HEATING SYSTEM
Please read these instructions carefully
before using the boiler.
These instructions are approved for Alde
Compact 3000 92X, 93X and 94X boilers
fitted in caravans, motor caravans and
buildings in accordance with CE no. 048 AP-
0013.
A professional may only carry out installation
and repairs. National regulations must be
adhered to.
IMPORTANT INFORMATION
- The LPG boiler and heating cartridge may
be operated in parallel.
- The heating system may be heated up
without the warm water heater being filled
with fresh water.
- Always drain the warm water heater of
fresh water if there is a risk of frost.
- The LPG boiler must not be operated
when filling the vehicle with fuel, in a
garage or elsewhere.
- The boiler must not be started if there is
no glycol in the system.
Note: If heating is to be operational
whilst unattended, ensure mains hook
up is connected. System can cause
battery to run flat, if battery is the sole
power source.
FAULT FINDING
The boiler does not start
1. No LPG?
2. Is the main tap fully open?
3. If the boiler has not been operated for
some time, or if the gas cylinder has been
changed, it may take longer than normal
to light the boiler.
4. Check that the boiler is connected to the
electricity supply (> 11 V).
5. Check that the fuse (T) for the boiler is
intact.
6. Check whether the overheating protection
has been tripped by unscrewing the black
plastic cap (U) and pressing the reset
button (V).
NB! If the overheating protection has
been tripped it cannot be reset until the
boiler has cooled down by 10-20°C.
Before restarting the boiler, check that it
has been properly bled.
7. Check whether the red LED on the
control panel has gone out. If not, switch
off the boiler. Wait 30 seconds and then
try restarting it.
8. Check that the boiler's electrical
connections are properly attached.
9. If none of these help, please contact a
service company.