Technical data

Services
33
Before you Start
1. Ensure pump is isolated.
2. Position lever in central, i.e. mixer, off
location.
COMET ROMA SINGLE LEVER MIXER TAP
Required tools
- Pipe wrench
- Cross-point
screw-driver
- Flat-bladed
screw driver
inside the
handle.
Step 1
- Remove the
marker cap
Step 2
- Remove the
screw from
the control
knob
- Pull the
microswitch
out of the
control knob
Step 3
- Remove the dome
- Remove the small
screw between
cartridge and closure
Step 4
- Remove the snap ring
(small plastic piece)
Step 5
- Remove the snap ring
with the Pipe wrench
(Turn left or right)
Step 6
- Pull the cartridge out of
the housing
- Remove the old
microswitch
Step 7
- Put in the cable from
the new microswitch.
You need 50 mm cable
length over the top of
the housing.
Step 8
- Insert the cartridge.
Step 9
- Refit the component parts in reverse
sequence.
Steps 5 to 1
Tools
1
43
5
6
2
9
7
8
1711 Caravan Owners Hbook 2006 21/7/05 6:04 pm Page 33