Service manual

14
5. To remove control panel parts.
(1) Remove the screw which secure the control panel, push up two snap fits and draw forward the control panel assembly.
(2) Remove the door open lever from the control panel.
(3) Remove three screws which secure the PCB assembly to control panel.
(4) Disconnect membrane tail from the connector of the PCB assembly.
(5) Detach membrane from the control panel.
(6) Remove door open button and button spring from the control panel.
(7) Reverse the above steps for reassembly.
REF NO. PART CODE PART NAME DESCRIPTION Q’TY
B01
3518524250
SWITCH MEMBRANE
KOG-1A0A9A
1
3518524260 KOG-1A6A9A
B02
3516722330
CONTROL-PANEL
KOG-1A0A9A
1
3516722340 KOG-1A6A9A
B03 PKMPMSX540 PCB AS KOG-131A9A11 1
B04 7122401211 SCREW TAPPING T2S TRS 4*12 MFZN 4
B05
3513702800
LEVER DOOR OPEN
KOG-1A0A9A
1
3513702310 KOG-1A6A9A
B06 441G430171 SPRING BUTTON SWP 1
B07
3516907940
BUTTON DOOR OPEN
KOG-1A0A9A
1
3516907950 KOG-1A6A9A