Service manual

8. FUNCTION OF THE CONVENIENT SERVICE
30
FUNCTION OF THE CONVENIENT SERVICE
■ The test mode of the load movement
You can check the PCB ASS'Y and the condition of each load movement simply.
• The method to enter
1 Press the Power switch button.
2 Press the Option button 3 times while press the Temp button.
At this time, the version is displayed on the Custom LED
3 Each load makes a movement as follows, whenever the Time Delay button is pressed a time.
1200(RPM) → C:H (Cold/Hot option)
→ L C (Lock Close) → H (Hot valve)
→ C (Cold valve) → P (Pre-Wash valve) → bb (bubble)
→ dr (drain pump) → L O (Lock switch Open)
■ The check mode of the water level frequency
You can check the beginning frequency and the frequency by the variation of the water level.
• The method to enter and operate
1 Press the Power switch button.
2 Press the Time Delay button 3 times while press the Temp button and the Spin button.
3 the beginning display on "18:88 LED" is the current frequency of the water level.
ex) 5 6 2 = 25.62kHz
: It display three number except the first number of 25.62kHz
4 When you press the Temp button a time → Cold valve On
2 times → Cold valve Off
3 times → Drain pump On