Specifications

5A2 – 68IAISIN AUTOMATIC TRANSAXLE
DAEWOO V–121 BL4
DTC P0742 Torque Converter Clutch (TCC) Circuit Stuck On
Step Action Value(s) Yes No
1
1. Turn the ignition OFF.
2. Install the Scan tool.
3. With the engine OFF, turn the ignition switch to
the ON position.
4. Select Store Freeze Frame/Failure Records
from the Diagnostic Trouble Codes Information
menu.
5. Store Freeze Frame/Failure Records.
6. Select Clear DTC Information from the Diag-
nostic Trouble Codes Information menu.
7. Clear DTC Information.
8. Perform two vehicle drive cycles.
Is the Malfunction Indicator Lamp (MIL) ON?
Go to Step 2 Repair the tem-
porary connec-
tion failure of
connector (Re-
fer to ”Wiring
Harness and
Connector” in
this section.)
2
1. Select Request DTC by Status from the Diag-
nostic Trouble Codes Information menu.
2. Request DTC by Status.
Is DTC P0742 displayed?
Go to Step 3 Repair the tem-
porary connec-
tion failure of
connector (Re-
fer to ”Wiring
Harness and
Connector” in
this section.)
3
1. Turn the ignition OFF.
2. Replace the master TCM and perform simula-
tion test again under user condition.
Is DTC P0742 reappeared?
Go to Step 4 Replace the
TCM
4
1. Estimate the failure of lockup solenoid, lockup
clutch or internal valve body.
2. Inspect the lockup solenoid. Refer to ”Unit In-
spection” in this section.
Is the condition of lockup solenoid OK?
Go to Step 5 Replace lockup
solenoid
5
1. Estimate the failure of lockup clutch or internal
valve body.
Is problem found?
Replace the
valve body as-
sembly
System OK