Specifications
AISIN AUTOMATIC TRANSAXLE 5A2 – 31
DAEWOO V–121 BL4
Input Speed Sensor
S Inspect resistance of each input speed senor be-
tween terminals.
Notice :
S Make sure to inspect resistance again at 20°C
(68°F) when resistance differ from standards ex-
cept 20°C (68°F).
S It might become infinity ohm when inspect resist-
ance at higher temperature.
Action : If the result of inspection is bad, replace ISS.
Transmission Range (TR) Switch
S Remove TR switch connector and inspect continuty
each range according to the conection chart.
Action : If the result of inspection is bad, replace the TR
switch.
Transmission Fluid Temperature Sensor
S Inspect the resistance between the terminals of
TFT sensor at 10°C (50°F) and 110°C (230°F).
Standard Value 10°C (50°F) 110°C (230°F)
5.80~7.09 kΩ 0.23~0.263 kΩ
Action : If the result of inspection is bad, replace the TFT
sensor.