53
5. REFRIGERANT CYCLE
INDOOR UNIT
Evaporator
Cross flow fan
Connecting pipe
Capillary tube
Dryer
Condenser
Propeller fan
OUTDOOR UNIT
Refrigerant flow
Service valve
Service valve
Accumulator
Compressor
Note) If the pipe length exceeds the standard length, add 30g of refrigerant per extra meter.
Contents
Model Name
Capillary Tube
Charge Quantity
DSA-123L
IDØ1.6 x L800
860 g
DSB-181L
IDØ2.0 x L650
1,150 g
DSB-182L
IDØ1.8 x L600
1,600 g
DSB-182L-R
IDØ2.0 x L1000
1,350 g
DSA-182L
IDØ1.8 x L600
1,450 g
DSA-183L-R
IDØ2.0 x L800
1,400 g
DSB-183L-R
IDØ2.0 x L1000
1,400 g
DSA-240L-R
IDØ2.0 x L400
1,550 g
Contents
Model Name
Capillary Tube
Charge Quantity
DSB-070L/071L
IDØ1.6xODØ3.2x900L
530 g
DSB-091L/092L
IDØ1.6xODØ3.2x1200L
630 g
DSB-121L/122L
IDØ1.6xODØ3.2x600L
1,310 g
DSB-123L
IDØ1.6xODØ3.2x600L
1,250 g
DSA-181L
IDØ2.0xL1000
1,430 g
DSB-240L-R
IDØ2.0xL500
2,050g
DSA-240L
IDØ2.0xL400
2,100g