Service manual
92
PROCEDURES PHOTOS 
1. Stop the operation of the Air conditioner and disconnect the power cord
from the wall outlet.
2. Removing the Insert Grille and Frame Grille. (Fig 1~2)
1 Draw up the Insert Grille and remove it.
2 Loosen two special screws fixed at the Cover Ter-Block.
3 Loosen three screws fixed at the Body.
4 Remove the Frame Grille.
3. Removing the Control Box. (Fig 3)
1 Remove room and coil thermistors.
2 Disconnect the fan motor lead wire from connection at the 
Control PCB.
3 Disconnect the stepping motor lead wire from connection at the 
Control PCB.
4 Remove the select switch from connection at the Control PCB.
5 Loosen the screw fixed at the ground wire.
6 Remove the Control Box
4. Removing the Drain Pan. (Fig 4)
1 Disconnect the Body drain hole. (left and right Body)
2 Disconnect three hooks and remove the Drain Pan.
5. Removing the Indoor Evaporator. (Fig 5~6)
1 Remove three screws fixed at the indoor Evaporator of the Body.
2 Remove the hook fixed at the Bracket Pipe of the back of Body.
3 Remove the Indoor Evaporator.
6. Removing the Cross Flow Fan. (Fig 7)
1 Remove set screw fixed at the Motor shaft.
2 Remove the Cross Flow Fan.
7. Remove Motor IDU and Bearing Plastic.