Manual de servicio Split Acondicionador de Aire Modelo: DSA-095L DSA-125L,125P DSA-185L,185P DSA-245L,245P Aviso: En este manual,algunas partes pueden cambiar sin previo aviso en la lista de partes si usted necesita la ultima informacion por favor dirigirse a PPL(Parts Price List)Centro de informacion de servicio(http.//svc.dwe.co.kr). http;//svc.dwe.co.
Contents CONTENTS 1. Specifications..........................................................................................................2 2. Outline and Dimensions .........................................................................................6 3. Operation ..............................................................................................................14 4. Wiring Diagram.....................................................................................................25 5.
1. SPECIFICATIONS ◆DSA-095L MODEL DSA-095L ITEM Function Cooling Class T1 Power AC 230V/ 60Hz Capacity KJ/h 9,000 Btu/h 8,531 l/h 1.1 Running Current A 3.6 Power Input W 800 Dehumidification Electrical Data Type Rotary Model QK125KB✳ (LGE) Compressor Capacitor Fan Motor 25µF / 400VAC Indoor Unit Outdoor Unit Type Cross flow fan Propeller fan Capacitor 1.0µF 400VAC 2.
◆DSA-125L, 125P MODEL DSA-125L, 125P ITEM Function Cooling Class T1 Power AC 230V/ 60Hz Capacity KJ/h 12,500 Btu/h 11,848 l/h 1.35 Running Current A 4.7 Power Input W 1,010 Dehumidification Electrical Data Compressor Type Rotary Model QK156KA✳ (LGE) Capacitor 35µF/ 370VAC Division Fan Motor Indoor Unit Outdoor Unit Type Cross flow fan Propeller fan Capacitor 1.
◆DSA-185L, 185P MODEL DSA-185L, 185P ITEM Function Cooling Class T1 Power AC 230V/ 60Hz KJ/h 17,500 Btu/h 16,588 l/h 2.0 Running Current A 7.2 Power Input W 1,620 Capacity Dehumidification Electrical Data Compressor Type Rotary Model QJ250KA✳ (LGE) Capacitor 35µF/ 370VAC Division Fan Motor Indoor Unit Outdoor Unit Type Cross flow fan Propeller fan Capacitor 1.
◆DSA-245L, 245P MODEL DSA-245L, 245P ITEM Function Cooling Class T1 Power AC 230V/ 60Hz KJ/h 23,500 Btu/h 22,275 l/h 2.7 Running Current A 10.0 Power Input W 2,220 Capacity Dehumidification Electrical Data Compressor Type Rotary Model QP325KBB (LGE) Capacitor 40µF/ 400VAC Division Fan Motor Indoor Unit Outdoor Unit Type Cross flow fan Propeller fan Capacitor 1.2µF 400VAC 3µF 400VAC IC-9430DWKF7A(Sung shin) A2929GS010(DMI) Motor Model Number Sound Level (Hi) dB(A) 48.
2. OUTLINE AND DIMENSIONS 1 INDOOR UNIT ◆DSA-095L 750 Connecting Pipe Plate Mounting MODE FAN SPEED ENTER/ CANCEL TIMER ON/OFF SLEEP REMOTE CONTROLLER FAN DIR.
◆DSA-125L, 125P 815 MODE FAN SPEED ENTER/ CANCEL TIMER ON/OFF SLEEP FAN DIR.
◆ DSA-185L, 185P Filter-L Connecting Pipe ¿‹ Æ˘˜ ˙` 453 453 1035 1035 Filter-R Plate ”fi `⁄˘˙ Mounting MODE FAN SPEED ENTER/ CANCEL TIMER ON/OFF SLEEP FAN DIR.
◆DSA-245L, 245P Connecting Pipe Filter-L 430 710 1080 Grille Insert MODE FAN SPEED ENTER/ CANCEL TIMER ON/OFF SLEEP FAN DIR.
◆INSTALLING THE INSTALLATION PLATE Unit : mm • DSA-245L, 245P • DSA-185L, 185P • DSA-125L, 125P • DSA-095L 10
2 OUTDOOR UNIT ◆DSA-095L Inlet Outlet Foot Cushion Cabinet Front SVC Cover 549 Cabinet Side Panel Top Guide Support 11 324 Servise Valve 539 Inlet Outlet 460 654 256 286
◆DSA-125L, 125P, 185L, 185P Inlet Outlet Foot Cushion Cabinet Front Cabinet Side Panel Top Guide Support 12 400 SVC Cover Servise Valve 589 615 Inlet Outlet 580 800 320 360
◆DSA-245L, 245P Inlet Outlet Foot Cushion Cabinet Front SVC Cover Servise Valve 673 697 Cabinet Side Panel Top Guide Support 13 Inlet Outlet 549 872 325 350 380
3. OPERATION 1 NAME AND FUNCTION OF PARTS ◆DSA-095L Indoor Unit Deodorizing Filter Removes bad smells from the air. Electrostatic Filter Removes dust particles from the air. Air In Indoor Cover Air Cleaning Filters Removes dust and prohibits germs. Connection Cover Fan Direction (Up/Down) Cold Air Remote Sensor Remove cover to access the AC connection from this unit to the outdoor unit. Indicators Indicate the setting .
◆DSA-125L, 125P Indoor Unit Electrostatic Filter Removes dust particles from the air (DSA-125L) Electric Dust Collector (Air clean Plasma) Removes small dust and generates (-) ions. (DSA-125P) Deodorizing Filter Removes bad smells from the air. Air In Indoor Cover Air Cleaning Filters Removes dust and prohibits germs. Fan Direction (Up/Down) Remote Sensor Cold Air Indicators Indicate the setting TE MP . MOD E O FA N/O N SP FF SL FA EE N EE P D D IR FA TIM . FA N N DI SP ER VAPS ON R.
◆ DSA-185L, 185P Indoor Unit Electrostatic Filter Removes dust particles from the air (DSA-185L) Electric Dust Collector (Air clean Plasma) Removes small dust and generates (-) ions. (DSA-185P) Deodorizing Filter Removes bad smells from the air. Test/Emergency/ Remote Switch Slide to select the desired position. Air In Indoor Cover Air Cleaning Filters Removes dust and prohibits germs. Remote Sensor Cold Air Indicators Indicate the AC setting. Fan Direction (Up/Down) TE FA MO MP N SP .
◆ DSA-245L, 245P Electrostatic Filter Removes dust particles from the air (DSA-245L) Deodorizing Filter Removes bad smells from the air. Electric Dust Collector (Air clean Plasma) Removes small dust and generates (-) ions. (DSA-245P) AIR IN Indoor Cover Air Cleaning Filters Removes dust and prohibits germs. AIR OUT Remote Sensor Fan Direction (Up/Down) Emergency/ Remote Switch Indicators Indicate the AC setting. FA FA MO DE N SP EE D N DI R. R.
2 REMOTE CONTROLLER Name of Each Button Display Displays information pertaining to unit. ( DSA-125P, 185P, 245P) AUTO ON/OFF Button Press to turn the unit on or off. FAN SPEED Button Press to select the fan speed (High " ", Middle " ", Low " "). MODE Button Press to cycle through the modes (Auto/Quick/Cool/Fan/Dehumidifier) SLEEP Button Press to set the unit for the sleep mode. TEMPERATURE Buttons Press to raise or lower the desired temperature. MODE FAN SPEED SLEEP FAN DIR.
3 DESCRIPTION OF FUNCTIONS OFF-Timer If you set time in OFF-Timer Mode, the unit will stop at the set time. ON Unit ON Unit OFF OFF SET Time HOUR ON-Timer If you set time in ON-Timer Mode, the unit will run at the set time.
Fan Speed (Indoor Unit) (1) Motor speed (high speed, normal speed, low speed). (2) Remote controller setting fan speed. (Auto, L, M, H, Natural) (3) Relation of operating mode between fan speed.
Sleep Mode (1) When you are going to sleep, select sleep switch and the unit controls the room to the desired temperature. (The unit will not operate after 4 hour) (2) For changing the temperature. DT +0.5°C +0.5°C +0.5°C 0 0.5 1.0 HOUR (COOLING CYCLE) (3) To cancel sleep mode, press the SLEEP button again or press the MODE button once.: the SLEEP indicator will disappear in the display.
Frost Prevention of Indoor Unit When the unit operates at low ambient temperature, frost may appear on the Evaporator. When the indoor coil temperature is lower than 0°C at the end of 10 minutes of continuous compressor operation from the start, the microcomputer of the unit stops the compressor to protect the unit from the frost. The control procedure for indoor coil freeze protection. 1) The compressor and outdoor fan turn off. 2) Indoor fan operates according to user set speed.
Dehumidification Mode 1 Desired temperature < Room temperature Outdoor Fan, Compressor : ON Indoor Fan : Low speed 2 Desired temperature ≥ Room temperature Compressor : 3 min/ON, 5 min/OFF Fan Speed : low speed 3 Room temperature ≤ 18°C Compressor : OFF Fan speed : Low speed Air Discharge Direction(only remocon operation) The air discharge direction procedure is below.
Self-Diagnostic Function The control will contain diagnostic test to verify the integrity of the system. (1)Error Code Display Pattern 1 ON LAMP: Blink LED BLINK PATTERN CASE NOTE Room Sensor open or Short • Continuously working to fix room temperature 18°C in cooling mode. • I/D coil sensor open or short Do not working • Compressor or electrical parts of compressor error. Continuously working 0.5s 8s 1 times blink • Gas leak 2 times blink Self Diagnostic Function Description 1.
4.
Indoor Unit ◆ DSA-125P ◆ DSA-185P ◆ DSA-245P 26
Outdoor Unit ◆ DSA-095L ◆ DSA-125L, 125P ◆ DSA-185L, 185P ◆ DSA-245L, 245P 27
5.
◆DSA-185L, 185P 29
◆DSA-245L, 245P 30
6. ELECTRIC CIRCUIT DIAGRAM 1 ELECTRIC CIRCUIT DIAGRAM ◆DSA-095L, 125L, 125P, 185L, 185P, 245L, 245P 1 Indoor Unit Fan Motor 2 3 N I.D.C L Y TERMINAL BLOCK L SWING MOTOR S R TRANSFORMER TRIAC RL1 COMP.
Description 1. After the power ON/OFF button is pressed once, the relay and triac are turned ON or OFF per the remote control setpoint. – TRIAC is controlled per the fan speed selection. – RELAY is controlled per the operation mode selection. 2. If the power ON/OFF button is pressed once more, the relay and triac are turn off and the unit stops operation. 3. The unit turns on or off according to the temperature set point by sensing the room air temperature through thermistor. 4.
7. TROUBLE SHOOTING Is the unit display mormal? YES NO NO check the failure code according to the self-diagonostic (note 2) Is the unit display normal? YES Outdoor unit does not run?(note.
Note 1) 1 Neither indoor unit nor outdoor unit runs. Check the following points first. (There are following case in normal operation) a. Is the timer mode set the "timer ON". b. Is the timer mode set the "timer-OFF" and the time had passed? 2 Neither outdoor fan nor compressor runs while indoor fan runs. Check following points first. (There are following cases in normal operation) a. Is the temperature set point suitable? b.
Neither Indoor Unit nor Outdoor Unit Runs Confirm following statement. When the unit operate normally, Sometimes the outdoor unit and indoor unit cannot operate. 1 Check the function select switch. Is it timer mode? 2 The function select switch locate the sleep mode and is the setting time over? 3 Is the setting mode DEHUMIDIFIER mode? 4 When the unit is DEHUMIDIFIER mode while in the auto mode, the outdoor unit and indoor unit does not run.
Outdoor Unit Runs but Indoor Fan Do Not Run Check rotation of indoor fan NO Check the Fan Motor bearing and fan Rating voltage Check the power P.C.B. Rotate indoor fan by hand YES Check input Voltage of Fan Motor connector at power P.C.
Outdoor Fan and Compressor Do Not Confirm following statement. When the unit operate normally, Sometimes the outdoor unit and indoor unit cannot operate. 1 Is the setting temperature proper? 2 Is the unit during 3min. Time delay of compressor. 3 During frost prevention of lndoor unit. 4 During dehumidifier mode.
Only Compressor Do not Run - Check the following at cooling mode Rating voltage Check the voltge between L and Y of indoor unit terminal less than 90% Check the control P.C.B the circuit for relay driving. Rating voltage more than 90% Rating voltage Check the voltge between L and Y of outdoor unit terminal less than 90% Check the connecting wire between indoor and outdoor.
8.
◆DSA-185L, 185P 40
◆DSA-245L, 245P 41
◆DSA-095L PART LIST (Control PCB Assy) ✔ Caution : In this Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need the latest parts information, please refer to PPL(Parts Price List) in Service Information Center (http://svc.dwe.co.kr). No. PART CODE PART NAME SPEC.
No. PART CODE PART NAME SPEC. Q'TY UNIT PCB 3104398104 PCB CONTROL 162.5X140X1.
◆DSA-125L, 125P PART LIST (Control PCB Assy) ✔ Caution : In this Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need the latest parts information, please refer to PPL(Parts Price List) in Service Information Center (http://svc.dwe.co.kr). No.
No.
◆DSA-185L, 185P PART LIST (Control PCB Assy) ✔ Caution : In this Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need the latest parts information, please refer to PPL(Parts Price List) in Service Information Center (http://svc.dwe.co.kr). No. PART CODE PART NAME SPEC.
No. PART CODE PART NAME SPEC. R1 RD-4K103J- R CARBON FILM 1/4 10K OHM J 1 EA R10 RD-4K562J- R CARBON FILM 1/4 5.6K OHM J 1 EA R11 RD-4K102J- R CARBON FILM 1/4 1K OHM J 1 EA R12 RD-4K102J- R CARBON FILM 1/4 1K OHM J 1 EA R13 RD-4K102J- R CARBON FILM 1/4 1K OHM J 1 EA R14 RD-4K102J- R CARBON FILM 1/4 1K OHM J 1 EA R16 RD-4K103J- R CARBON FILM 1/4 10K OHM J 1 EA R17 RD-4K103J- R CARBON FILM 1/4 10K OHM J 1 EA R18 RN-4K1272F R METAL FILM 1/4 12.
◆DSA-185L, 185P PART LIST (Power PCB Assy) ✔ Caution : In this Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need the latest parts information, please refer to PPL(Parts Price List) in Service Information Center (http://svc.dwe.co.kr). No. PART CODE PART NAME SPEC.
◆DSA-245L, 245P PART LIST (Control PCB Assy) ✔ Caution : In this Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need the latest parts information, please refer to PPL(Parts Price List) in Service Information Center (http://svc.dwe.co.kr). No. PART CODE PART NAME SPEC.
No. PART CODE PART NAME SPEC. Q'TY UNIT J1 14 3109400100 JUMPER 10MM 14 EA J1~14 3109400100 JUMPER 10MM 14 EA COIL 130UF 3A 1 EA RESONATOR CRTL8.00MSOT 1 EA L1 52C1374001 OSC 5PCRTL8MS0 PCB 3104398102 PCB MAIN 160.5*140*1.6T(42) 1 EA PT1 1TLP560J-- IC PHOTO COUPLER TLP 560J 1 EA R1 RD-4K101J- R CARBON FILM 1/4 100 OHM J 1 EA R10 RN-4K1272F R METAL FILM 1/4 12.7K OHM F 1 EA R11 RN-4K1272F R METAL FILM 1/4 12.
◆LED PCB ASS`Y (MODEL : DSA-095L) No PART CODE PART NAME CC1 CN1 HOLD L1 L2 L3 L4 PCB RCV SW1 CDXE1H104M 3108804800 3103002700 DDLS05031D DDLG05031D DDLS05031D DDLY05031D 3104398201 1TSP1838YA 5S40202000 C-MULTI WAFER HOLDER LED LED LED LED LED PCB LED RECEIVER MODULE S/W PUSH SPEC CR501B-Z5U,104Z,50V SMAW250-08 ABS DLSO-5031D(RED) DLG-5031D(GRN) DLSO-5031D(RED) DLY-5031D(YLW) 110*31*1.6T.
Power Supply(1) AC 220V FUSE1 12V VAR D2 D1 275V 104K CC1 CE1 IC2 7812 CC2 5V CE2 + 3.15A D4 D3 G VI VO + 104 35V 1000µF 104 25V 470µF IC3 7805 VI VO CC3 G CL1 CE3 + 104 16V 100µF POWER TRANS DESCRIPTION DC Power Supply in circuit needs +12V and +5V. +12V is used for Compressor Driving Relay, Triac Driving Photo Triac, Buzzer Driving Swing, Sweep Motor. AC voltage of secondary Power Transformer is rectified by Bridge Diode, and it is filtering by Main Condensor CE1.
DESCRIPTION Oscillatory Frequency drive Micom, it is made up 8MHz resonator oscillatory Freqency. Ocillatory wave is as following Fig 2-1. VDD-10% VSS+10% Fig 2-1 Sensor(3) Room temperature and Evaporator temperature Sensor Input 070LH,091LH 182LH, 240LH 330 R8 23 O/C SENSOR CN10 R9 12.7kF CC7 103 MICOM 103 CC6 CN9 24 I/C SENSOR R10 12.7KF R7 330 ROOM SENSOR R11 12.7KF R6 330 25 CC5 103 DESCRIPTION Number 24, 25 of Micom is Terminal of A/D convertor Input.
Triac Driving(4) 12V N L1 TLP561 PT1 1 AC 220V 2 L 130 H 3A MICOM T1 SM3JZ47 IC4 KID 65004 38 2 15 R5 SN1 0.1 F 120Ohm TO MOTOR 1K 1/2W DESCRIPTION Number 38 Terminal of Micom is put out Pulse Output, by way of Buffer it is driving Photo Triac is supplied Trigger Signal. Trigger Test of Triac is detected Zero Cross Part of AC input and it is triggered from Zero Cross part to Time delay part according to Fan Speed. (Ref. Fig 4-1) SN1 is Snubber.
Remote Controller(5) DESCRIPTION Signal from Remote Controller put in only Control Data Signal at Micom Terminal of Number 33, which is gotten fid of Carrier (38KHz) from Receive Module. Signal Wave repeat third as following Fig 5-1. But in Secondary Wave Custom Code is Reversed Face. 9ms 4.5ms 16bit 24bit 8bit 16bit 0.56ms LEADER CODE CUSTOM CODE DATA CODE CHECK SUM 1.69ms 1.12ms bit 0 TAILER 2.
Micom Power Supply(7) 5V VDD 42 CE5 10µF 16V + CC11 104 41 MICOM OSC 8MHz 40 39 19 20 21 VSS 22 CC13 104 DESCRIPTION MICOM Power is supplied 5V at Number 42 using VDD, Number 19, 20 Vsing Oscillator, CC13 is noise filter.
Reset(8) MICOM R13 5.6K 1K R12 18 7042P CC9 10.3 IC5 CE4 4.7uF/50V DESCRIPTION Voltage less than about 0.8V put in Micom Terminal of Number 18 and then Micom reset. Reset IC detect Power ON and Voltage less than 4.25V, and then send Reset Signal. Vcc (+5V) 4.
Function Selecting(9) CA3 F3 104Z 41 RA3 4A 103J RA3 R32 1K JS5 R31 1K JS4 MILD/HIGH 40 39 HEAT/COOL R30 1K MICOM 30 model JS3 1K R17 JS2 1K R16 29 14 RA2 6A 103J RA1 27 16 CA2 R36 heat/low 1K R28 1K R25 1K R24 R33 cool/high 1K R23 R37 monitoring 1K R29 28 15 1K R15 JS1 F5 104Z CA1 26 R35 cool/low R34 heat/high DESCRIPTION Selecting function is as following table 9-1. * When power source is put at fist, Funtion selection input is recognized.
Zero Crossing Detect(11) VCC R3 10K 2 TR1 KRC120M D5 2 1 R27 1K MICOM 31 3 R2 5.6K 1 D6 2 TRANS OUTPUT 1 CC4 103 2 1 DESCRIPTION It defect Zero Cross part of Trans output voltage, Transistor TR1 is used to put in the Micom. Detail Driving is as following Fig 11-1. R19 is Resistance to limit current.
Stepping Motor Driving(12) 12V CN13 1 IC6 MICOM B+ 2 1 3 Ø1 2 4 Ø2 3 5 4 6 M1 FOR SWING Ø3 Ø4 KID65004 DESCRIPTION There are one Stepping Motor for Flap (up and down) and it is used 4 face Drive Method. It is driving as following Fig 12-1.
2 REMOTE CONTROLLER ASSMBLY FUNCTIONAL TEST METHOD TEST START No Power supply again Power Supply Is Display at the beginning ON? Select ON/OFF button Yes Is Display at the beginning ON? No Select Mode button Is it normal? No ERROR Select FAN SPEED button Is it normal? Select FAN DIR. button Is it normal? Is display at the begining ON? Select TEMP. Button (▲,▼) Is it normal? No ERROR ( ▲) ▼ No ERROR No ERROR (Whenever you selectted Temp.
Is LCD display OFF? No ERROR Select TIMER ON Button Is it normal No ERROR Select Timer Enter Button TIMER display? No ERROR Select CANCEL Button Is all display OFF? No ERROR Select ON/OFF Button Select OFF (Timer) Button Is it normal? (0.
9.
(2) U2, 4 (KID65004) DARLINGTON ARRAYS 16 OUT 1 15 OUT 2 14 OUT 3 13 OUT 4 12 OUT 5 11 OUT 6 10 OUT 7 9 COMMON FREE WHEELING DIODES KID65004AP COMMON INPUT OUTPUT 10.5KΩ 7.2KΩ 3KΩ IN1 1 IN2 2 IN 3 3 IN 4 4 IN5 5 IN6 6 IN7 7 GND 8 (Equivalent Circuit) (Top View) (3) U8 (KIA7805P) : VOLTAGE REGULATOR (5VDC) SCHEMATIC DIAGRAM INPUT 100K 100 100 500 10K 240 200 3.3 K 1 2 3 Pin 1. INPUT 2. GROUND 3. OUTPUT OUTPUT 2K 6K 0.19K 1.4 K 2.7 K 0.
(5) U9 (KIA7042P) : RESET IC 1 VCC KIA70 42P 3 OUT 2 GND INPUT GROUND OUTPUT OUTLINE 65
10. DISASSEMBLY INSTRUCTIONS 1 INDOOR UNIT ◆DSA-095L, DSA-125L, 125P PROCEDURES PHOTOS 1. Stop the Air conditioner and disconnect the power cord from the wall outlet. Fig 1 2. Removing the Insert Grille and Frame Grille. (Fig 1~2) 1 Draw up the Insert Grille and remove it. 2 Loosen one screw for fixing the Cover Ter-Block. 3 Loosen two screw at the Frame Grille. 4 Remove the Frame Grille. 3. Removing the Control Box. (Fig 3) 1 Remove room and coil thermistors.
◆DSA-185L, 185P PROCEDURES PHOTOS 1. Stop the Air conditioner and disconnect the power cord from the wall outlet. 2. Removing the Insert Grille and Frame. ! Loosen three screws for fixing the the Insert Grille and Frame. (Pull out the frame cap before loosening three screws) (Fig 1) @ Loosen three screws at the Drain Pan. # Remove the Insert Grille and Frame. 3. Removing the Control Box. After doing above procedures: ! Disconnect indoor room and coil thermistors.
PROCEDURES PHOTOS 7. Removing the blower. After doing above procedures: ! Loosen a screw for fixing holder bearing. @ Remove the blower.
◆DSA-245L, 245P PROCEDURES PHOTOS 1. Stop the operation of the Air conditioner and disconnect the power cord from the wall outlet. Fig 1 2. Removing the Insert Grille and Frame Grille. (Fig 1~2) 1 Draw up the Insert Grille and remove it. 2 Loosen the screws fixed at the Cover Ter-Block. 3 Loosen two screw at the Frame Grille. 4 Remove the Frame Grille. 3. Removing the Control Box. (Fig 3) 1 Remove room and coil thermistors. 2 Disconnect the fan motor lead wire from connection at the Control PCB.
2 OUTDOOR UNIT ◆DSA-095L PROCEDURES PHOTOS 1.Stop the operation of the air conditioner and disconnect the wire from Indoor Unit to Outdoor Unit. 2. Disassemble the case. (Fig 1~2) 1 Remove the Top Panel. (Loosen thirteen screws) 2 Remove the Front Cabinet. (Loosen six screws) 3 Remove the Side Cabinet. (Loosen seven screws) 4 Remove the Guide Support. (Loosen two screws) 3. Removing the Propeller Fan. (Fig 3) 1 Loosen the Nut fixed at the the Propeller Fan. 2 Remove the Plain Washer.
◆DSA-125L, 125P, DSA-185L, 185P PROCEDURES PHOTOS 1.Stop the operation of the air conditioner and dis connect the wire from in door unit to out door unit. 2. Disassemble the case. (Fig 1~2) 1 Remove the Top Panel. 2 Remove the Side Cabinet. 3 Remove the Front Cabinet. Fig 1 Fig 2 3. Removing the Propeller Fan. (Fig 3) 1Loosen the screw fixed at the motor bracket. 2Remove the Plain Washer. 3Remove the Propeller Fan. 4. Remove the panel control. (Fig 4) 1Disconnect the wire at the control panel.
◆DSA-245L, 245P PROCEDURES PHOTOS 1.Stop the operation of the air conditioner and disconnect the wire from in door unit to out door unit. 2. Disassemble the case. (Fig 1~2) 1 Remove the Top Panel. 2 Remove the Front Cabinet. 3 Remove the Side Cabinet and Back Cabinet. Fig 1 3. Removing the Propeller Fan. (Fig 3) 1Loosen the screw fixed at the motor bracket. 2Remove the Plain Washer. 3Remove the Propeller Fan. Fig 2 4. Removing the panel control. (Fig 4) 1Disconnect the wire at the control panel.
3 EXPLODED VIEW & PARTS LIST (Indoor Unit) ◆INDOOR UNIT EXPLODED VIEW: DSA-095L 73
◆INDOOR UNIT PART LIST; DSA-095L ✔ Caution : In this Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need the latest parts information, please refer to PPL(Parts Price List) in Service Information Center (http://svc.dwe.co.kr). No PART CODE PART NAME Q'TY 1 3100400301 BODY 1 HIPS T2.
◆INDOOR UNIT EXPLODED VIEW: DSA-125L, 125P 26-1 75
◆INDOOR UNIT PART LIST; DSA-125L, 125P ✔ Caution : In this Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need the latest parts information, please refer to PPL(Parts Price List) in Service Information Center (http://svc.dwe.co.kr). No PART CODE PART NAME Q'TY 1 3110400301 BODY 1 HIPS T2.0 2 3118003500 MOTOR IDU 1 RB13B(220V, 50/60V) 3 3106400400 BEARING PLASTIC Ass`y 1 4 3110046000 FAN CROSS FLOW Ass`y 1 SAN+G.
◆INDOOR UNIT EXPLODED VIEW: DSA-185L, 185P t 0 o w d 3 ; a p 8 2 r 9 7 l i y 16-1 6 z h 4 s f x u g e c k j q 5 1 77
◆INDOOR UNIT PART LIST; DSA-185L, 185P ✔ Caution : In this Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need the latest parts information, please refer to PPL(Parts Price List) in Service Information Center (http://svc.dwe.co.kr).
◆INDOOR UNIT EXPLODED VIEW: DSA-245L, 245P 27 28 28-1 79
◆INDOOR UNIT PART LIST; DSA-245L, 245P ✔ Caution : In this Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need the latest parts information, please refer to PPL(Parts Price List) in Service Information Center (http://svc.dwe.co.kr).
4 EXPLODED VIEW & PARTS LIST (OUTDOOR UNIT) ◆OUTDOOR UNIT EXPLODED VIEW: DSA-095L 81
◆OUTDOOR UNIT PART LIST; DSA-095L ✔ Caution : In this Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need the latest parts information, please refer to PPL(Parts Price List) in Service Information Center (http://svc.dwe.co.kr). No PART CODE PART NAME Q'TY 1 3100014720 PAN BASE Ass`y 1 SECC T1.2 2 3106000900 COMP. BOLT 3 M8 x L46.5 3 3102100800 FOOT 1 SECC T1.2 4 3108104AE0 COMP.
◆OUTDOOR UNIT EXPLODED VIEW: DSA-125L, 125P 83
◆OUTDOOR UNIT PART LIST; DSA-125L, 125P ✔ Caution : In this Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need the latest parts information, please refer to PPL(Parts Price List) in Service Information Center (http://svc.dwe.co.kr). No PART CODE PART NAME Q'TY 1 3110007500 PAN BASE Ass`y 1 2 3102100201 FOOT 4 SECC T2.0 3 3106000100 BOLT COMP. 3 M8xL46.5 4 3117104390 COMPRESSOR Ass`y 1 QK164K** 5 3108104AE0 COMP.
◆OUTDOOR UNIT EXPLODED VIEW: DSA-185L, 185P 85
◆OUTDOOR UNIT PART LIST; DSA-185L, 185P ✔ Caution : In this Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need the latest parts information, please refer to PPL(Parts Price List) in Service Information Center (http://svc.dwe.co.kr). No PART CODE PART NAME Q'TY 1 3110007500 PAN BASE Ass`y 1 2 3102100201 FOOT 4 SECC T2.0 3 3106000100 BOLT COMP. 3 M8xL46.5 4 3117104390 COMPRESSOR Ass`y 1 QJ250K** 5 3108104AE0 COMP.
◆OUTDOOR UNIT EXPLODED VIEW: DSA-245L, 245P 87
◆OUTDOOR UNIT PART LIST; DSA-245L, 245P ✔ Caution : In this Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need the latest parts information, please refer to PPL(Parts Price List) in Service Information Center (http://svc.dwe.co.kr). No PART CODE PART NAME Q'TY 1 3100031102 BASE PAN Ass`y 1 SECC T1.2 2 3102100901 FOOT 2 SECC T1.6 3 3106003100 BOLT COMP 3 M8*P1.
5 CONTROL BOX ASSEMBLY ◆DSA-095L 3 8 7 4 6 2 9 1 0 q 5 89
◆DSA-095L ✔ Caution : In this Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need the latest parts information, please refer to PPL(Parts Price List) in Service Information Center (http://svc.dwe.co.kr). No PART CODE PART NAME Q'TY 1 3114302010 CONTROL PCB ASS’Y 1 2 3108914100 TERMINAL BLOCK 1 JXO-CH-3P 3 3106900300 CAPACITOR SH.M.B 1 1.
◆DSA-125L, 125P 9 91
◆DSA-125L, 125P ✔ Caution : In this Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need the latest parts information, please refer to PPL(Parts Price List) in Service Information Center (http://svc.dwe.co.kr). No PART CODE PART NAME Q'TY 1 3110504000 CONTROL BOX 1 HIPS T2.
◆DSA-185L, 185P 93
◆DSA-185L, 185P ✔ Caution : In this Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need the latest parts information, please refer to PPL(Parts Price List) in Service Information Center (http://svc.dwe.co.kr).
◆DSA-245L, 245P ✔ Caution : In this Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need the latest parts information, please refer to PPL(Parts Price List) in Service Information Center (http://svc.dwe.co.kr).
◆DSA-245L, 245P 95
DEAWOO ELECTRONICS CO., LTD 686, AHYEON-DONG MAPOGU, SEOUL, KOREA. C.P.O. BOX 8003 SEOUL KOREA TELEX: DWELEC K28177-8 CABLE:"DAEWOOELEC" FAX: +82-2-364-5588 TEL: +82-2-360-7114, 8114 http://www.dwe.daewoo.co.kr S/M NO. : 3113914300 PRINTED DATE: MAR.