Specifications

FUNCTIONS
LED Lamp
- ERROR DISPLAY
- To check the appliance has error or not, push TEMP button 5 times while opening the refrigerator. door.
- To stop the Error Display Set, push “TEMP” button 1 times, or wait 4 minutes.
A. R1 ERROR (It happens when R-Sensor is OPEN or SHORT)
- DISPLAY : 3rd LED is on & off continually.
- CONTROL :
; Controlled by the following condition of RT
; When “RT ERROR” happens at the same time, “COMP. ON/OFF Operating Time” is 16min/24min.
(Unit : min)
- Termination : when R-Sensor is normal.
B. RT ERROR (It happens when RT-Sensor is OPEN or SHORT)
- DISPLAY : 2nd LED is on & off continually.
- CONTROL : Delete the conditions of “RT-sensor Control” and operate normally.
Termination hen R
Sensor is normal
CONTROL OBJECTINPUT
PCB Control Panel Buttons / Door
7. Error Display
6
/
34
~13C
10
/
30
~19C
16
/
24
~29C
20
/
20
COMP. Operating TIME
(ON/OFF)
29C ~RT sensor TEMP
-
T
erm
i
na
ti
on
:
w
h
en
R
-
S
ensor
i
s
norma
l
.
C. D1 ERROR (It happens when D-Sensor is OPEN or SHORT)
- DISPLAY : 1st LED is on & off continually.
- CONTROL : Defrosting is active maximum time (40 min)
- Termination: when D-Sensor is normal.
D. DR ERROR (It happens when the system senses door opens more than 1 hour.)
- DISPLAY : 2nd & 3rd LED are on & off continually.
- CONTROL : Deletion of function related door switch sensing
- If door switch (open & close) is sensed, the error is terminated automatically.
E. C1 ERROR (When D-Sensor is more than -5C, Comp operates continuosely over 3 hrs)
- DISPLAY : 1st & 3rd LED are on & off continually.
- CONTROL : Normal operation.
- Termination : When Comp is off, D-Sensor is less than -5C.
F. F3 ERROR (When defrosting is active for 60 minutes. )
6.1- DISPLAY : 1st & 2nd LED are on/off continually.
6.2- CONTROL : Skip the Pre-cool process.
6.3- Termination: When defrosing ends by the defrost sensor.
- If the appliance is normal (no error), just 4th and 5th LED is on/off in Error Mode.
11