Service manual

16
Standard Check point
1. Power source : 100 - 240Vac, 50/60Hz.
2. Aging : Take at least 20 minutes warm-up time.
3. Signal
• Video input : Analog 0.7Vpp 75terminal positive polarity
• Synchronizing : acceptable negative or positive at TTL level
• Max. Resolution :
15-1024 x 768@75Hz
• Frequency:
15”-Horizontal : 30KHz - 62KHz
Vertical : 50Hz - 75Hz (available only non interlace mode)
Adjustment
1. Sharpness set to 0%
2. Contrast set to 100%
3. Brightness set to 100%
4. Switching to factory alignment mode
Press power key with Brightness left key at the power off status.
5. Set up the tracking
See the SVC manual at page 14th.
6. Switching to users mode
If turn-off and turn-on then switched to user’s mode.
*
All of adjusted data stores by fade out of OSD.
ALIGNMENT PROCEDURE