Technical data
LVD TEST REPORT
Report Numbe r : KSQ-LVD 081010
Clause Requirement - Te st Result - Remark Verdict
Page 9 / 63
8.1.2
Use of test probe 13 of IEC 61032 through openings
in class 0 appliances and class II appliances/
constructions: no contact with live parts
No opening N
Test probe 13 also applied through openings in
earthed metal enclosures having a non-conductive
coating: no contact with live parts
N
8.1.3
For appliances other than class II, use of test probe
41 of IEC 61032: no contact with live parts of visible
glowing heating elements
No visible glowing heating
elem ents
N
8.1.4
Accessible part not considered live if:
N
- safety extra-low a.c. voltage: peak value not
exceeding 42.4 V
No SELV N
- safety extra-low d.c. voltage: not exceeding 42.4 V N
- or separated from live parts by protective
impedance
N
If protective impedance: d.c. current not exceeding
2 mA, and
N
a.c. peak value not exceeding 0.7 mA
N
- for peak values over 42.4 V up to and including 450
V, capacitance not exceeding 0,1 Fμ
N
- for peak values over 450 V up to and including 15
kV, discharge not exceeding 45 Cμ
N
8.1.5 Live parts protected at least by basic insulation before installation or assembly: P
- built-in appliances
No built-in applian ces N
- fixed appliances
P
- appliances delivered in separate units
No separate units N
8.2
Class II appliances and constructions constructed
so that there is adequate protection against
accidental contact with basic insulation and metal
parts separated from live parts by basic insulation
only
N
Only possible to touch parts separated from live
parts by double or reinforced insulation
P
9
STARTING OF MOTOR-OPERATED APPLIANCES
Requirem ents and tests are specified in part 2 when
necessary
N