Technical data
LVD TEST REPORT
Report Numbe r : KSQ-LVD 081010
Clause Requirement - Te st Result - Remark Verdict
Page 8 / 63
7.13 Instructions and other texts in an official language N
7.14 Markin g cle arly legible and durab le M ain label P
The height of symbol 5036 of 60417-1 shall be at
least 10 mm
N
The height of the lettering of the warning relating to
high voltage shall be at least 3 mm
P
7.15
Markingonamainpart
P
Marking clearly discernible from the outside, if
necessary after removal of a cover
P
For portable appliances, cover can be removed or
opened without a tool
Fixed appliances N
For stationary appliances, name, trademark or
iden tificatio n mark and mod e l or type refere nc e
visible after installation
N
For fixed appliances, name, trademark or
iden tificatio n mark and mod e l or type refere nc e
visible after installation according to the instructions
P
Indications for switches and controls placed on or
near the componen ts. Marking not on parts which
can be positioned or repositioned in such a way that
the marking is misleading
P
7.16
Marking of a possible replaceable thermal link or
fuse link clearly visible with regard to replacing the
link
N
8 PROTECTION AGAINST ACCESS TO LIVE PARTS
8.1
Adequate protection against accidental contact with
live pa r t s
P
8.1.1
Requirement applies for all positions, detachable
parts removed
Co m p lied P
Insertion or removal of lamps, protection against
contact with live parts of the lamp cap
No lamps. N
Use of test probe B of IEC 61032: no contact with
live pa r t s
P
Test finger can touch earthed parts of secondary
circuit when grid voltage is obtained from an
isolation transformer .
N