Technical data

LVD TEST REPORT
Report Numbe r : KSQ-LVD 081010
Clause Requirement - Te st Result - Remark Verdict
Page 7 / 63
When using extension cords, keep the socket-outlet
away from moisture and avoid damage to the cord
N
The instructions shall state the substance of the following :
N
- the appliance is to be kept out of reach of children
N
- the appliance is not to be used in locations where
flamm able vapour or explosive dust is likely to exist
N
The instructions shall give details concerning :
N
The method and frequency of cleaning, together
with the precau tio ns to be taken
N
Precautions to be taken when replacing laps and
starte rs
N
If symbol 5036 of IEC 60417-1 is used, its meaning
shall be explained
N
7.12.1
Sufficient details for installation supplied
Provide. P
7.12.2
Stationary appliances not fitted with means for
disconnection from the supply mains having a
contact separation in all poles that provide full
disco n n ec tion und er ove rv olta g e catego ry III, the
instructions state that means for disconnection must
be incorporated in the fixed wiring in accordance
with the wiring rule s
Not for permanent connection.
P
7.12.3
Insulation of the fixed wiring in contact with parts
exceeding 50 K during clause 11; instructions
stating that the fixed wiring must be protected
Not such part. N
7.12.4 Instructions for built-in appliances: N
- dimensions of space
N
- dimensions and position of supporting means
N
- distances between parts and surrounding
structu re
N
- dimensions of ventilation openings and
arrangement
N
- connection to supply mains and interconnection of
separate components
Provided for remote units. N
a switch complying with 24.3
N
7.12.5
Replacement cord instructions, type X attachment
with a specially prepared cord
N
Replacement cord instructions, type Y attachment
See the manual P
Replacement cord instructions, type Z attachment
P