Technical data

LVD TEST REPORT
Report Numbe r : KSQ-LVD 081010
Clause Requirement - Te st Result - Remark Verdict
Page 5 / 63
5 GENERAL CONDITIONS FOR THE TESTS
Tests performed according to cl. 5, e.g. nature of
supply, sequence of testing, etc.
P
6
CLASSIFICATION
6.1 Protection against electric shock: Class I, II Class II appliance P
6.2 Protection against harmful ingress of water IPX 0 P
Insect killer intended for outdoor use is at least IPX4 N
7
MARKING AND INSTRUCTIONS
7.1
Ra te d voltage or voltage rang e (V)..........................:
220V P
Na tu re of sup p ly.......................................................:
AC P
Ra te d freque n cy (Hz)...............................................: 50Hz / 60Hz P
Ra te d powe r inp u t (W):............................................: 120W P
Ra te d curre n t (A) .....................................................: P
Manufacturer's or responsible vendor's name ,
trade mark or identifica tion ma rk..............................:
DAEWOO ENERTEC Co.,
Ltd.
P
Mo d e l or type refere n c e ...........................................: DW050-100W220V P
Symbol 5172 of IEC 60417, for Class II appliances Symbol 5172 of IEC 60417 P
IP numbe r, othe r than IPX0 .....................................:
IPX 0 N
Symbol or warning for high voltage
N
Appliances provided with replaceable lamps marked
with the type reference of the lamp
N
7.2
Warning for stationary appliances for multiple supply
No m ultip le supply N
Warning plac ed in vici nity of ter minal cover
N
7.3
Range of rated values marked with the lower and
upper limits separated by a hyphen
No range of rated values P
Different rated values marked with the values
separated by an oblique stroke
N
7.4
Appliances adjustable for different rated voltages,
the voltage setting is clearly discernible
One rated voltage P