Technical data

LVD TEST REPORT
Report Numbe r : KSQ-LVD 081010
Clause Requirement - Te st Result - Remark Verdict
Page 49 / 63
- pollution degree 2: only non-conductive pollution
occurs, except that occasionally a temporary
conductivity caused by condensation is to be
expected
N
- pollution degree 3: conductive pollution occurs or
dry non-conductive pollution occurs that becomes
conductive due to condensation that is to be
expected
N
- pollution degree 4: the pollution generates
persistent conductivity caused by conductive dust
or by rain or snow
N
N
ANNEX N (NORMATIVE) PROO F TRACKING TEST
The proof tracking test is carried out in accordance
with IEC 60112 with the following modifications:
N
5 Test apparatus N
5.1
Electrodes
N
The note does not apply
N
5.4
Test solutions
N
Test solution A is used N
6 Procedure N
6.3 Proof tracking test N
Vo lta ge is 10 0 V , 175V, 400 V or 600 V .....................:
N
Note3ofclause3applies
N
The test is carried out on five specimens
N
In case of doub t, additional test with voltage
reduced by 25V, the number of drops increased to
100
N
7 Report N
The report stating if the PTI value was based on a
test using 100 drops with a test voltage of (PTI-25) V
N
O
ANNEX O (INFORMATIVE) SELECTION AND SEQUENCE OF THE TESTS OF
CLAUSE 30
Description of tests for determination of resistance
to heat and fire
P