Technical data
LVD TEST REPORT
Report Numbe r : KSQ-LVD 081010
Clause Requirement - Te st Result - Remark Verdict
Page 46 / 63
Subclause 17.2.5.2 is not applicable N
Temperature rise of the terminals not more than 30
K above the temperature rise measured in clause
11 of IEC 60335-1
N
20
Clearances, creepage distances, solid insulation and coatings of rigid printed
board assemblies
N
This clause is applicable to clearances and
creepage distances for functional insulation, across
full disconnection and micro-disconnection, as
stated in table 24
N
I
ANNEX I (NORMATIVE) MOTORS HAVING BASIC INSULATION THAT IS
INADEQUATE FOR THE RATED VOLTAGE OF THE APPLIANCE
N
The following modifications to this standard are
applicable for motors having basic insulation that is
inadequate for the rated voltage of the appliance:
N
8
Protection against access to live parts
N
8.1
Metal parts of the motor are considered to be bare
live pa r t s
N
11 Heating N
11.3
Temperature rise of the body of the motor is
determined instead of the tempe rature rise of the
windings
N
11.8
Temperature rise of the body of the motor, where in
contact with insulating material, not exceeding
value s in tab le 3 for the relevant insulat i ng material
N
16
Leakage current and electric strength
N
16.3
Insulation between live parts of the motor and its
other metal parts not subjected to the test
N
19
Abnormal operation
N
19.1
The tests of 19.7 to 19.9 not carried out
N
19.101 Appliance operated at rated voltage with each of the following fault conditions: N
- short circuit of the terminals of the motor, including
any capacitor incorporated in the motor circuit
N
- short circuit of each diode of the rectifier
N
- open circuit of the supply to the motor N
- open circuit of any parallel resistor, the motor being
in operation
N