Technical data

LVD TEST REPORT
Report Numbe r : KSQ-LVD 081010
Clause Requirement - Te st Result - Remark Verdict
Page 40 / 63
Glow-wire test of IEC 60695-2-11, the temperature being: P
-750°C, for connections carrying a current
exceeding 0,2A during normal operation
P
-650°C, for other connections
N
Parts that during the test produce a flame persisting
longer than 2 s, tested as specified
N
If a flame persists longer than 2 s during the test,
parts above the connection, as specified, subjected
to the needle-flame test of annex E, unless
N
the material is classified as V-0 or V-1 according to
IEC 60695-11-10
N
30 .2 .4
Base material of printed circuit boards subjected to
needle-flame test of annex E
N
Test not applicable to conditions as specified N
31 RESISTANCE TO RUSTING
Relevant ferrous parts adequately protected against
rusting
P
Appliances intended for outdoor use tested
according to IEC 60068-2-52 (severity 2)
P
32
RADIATION, TOXICITY AND SIMILAR HAZARDS
Appliance does not emit harmful radiation P
Appliance does not present a toxic or similar hazard P
Lamps do not e mit significant UV radiation; Total
Effe ctive Irradian ce < 1m W/m
2
N
A ANNEX A (INFORMATIVE) ROUTINE TESTS
Description of routine tests to be carried out by the
manufacturer
N
B
ANNEX B (NORMATIVE) APPLIANCES POWERED BY RECHARGEABLE
BATTERIES
The following modifications to this standard are
applicable for appliances powered by batteries that
are recharged in the appliance
N