Technical data
LVD TEST REPORT
Report Numbe r : KSQ-LVD 081010
Clause Requirement - Te st Result - Remark Verdict
Page 39 / 63
External parts: at 40 °C plus the maximum
temperature rise determined during the test of
clause 11, or at 75 °C, whichever is the higher;
tem p e ra tu re (°C)....................................................:
N
P arts su ppo r t ing live p arts: at 40° C plus the
ma ximum temp e ratu re rise determined du ring the
test of clause 11, or at 125°C, whichever is the
high e r; tem p e rature (°C)..........................................:
N
Parts of thermoplastic material providing
supplementary or reinforced insulation, 25°C plus
the maximum temperature rise determined during
claus e 19, if highe r; temp e ra tu re (°C)......................:
N
30.2
Relevant parts of non-metallic material adequately
resistant to ignition and spread of fire
P
30 .2 .1
Glow-wire test of IEC 60695-2-11 at 550 °C, unless
Enclosure inside P
the material is classified at least HB40 according to
IEC 60695-11-10
N
Parts for which the glow-wire test cannot be carried
out meet the requirements in ISO9772 for category
FH3 material
Non FH3 material N
30 .2 .2
Appliances operated while attended, parts of insulating material supporting
current-carrying connections and parts within a distance of 3mm subjected to the
glow-wire test of IEC 60695-2-11 at a temperature of:
N
30 .2 .3
Appliances operated while unattended, tested as
specified in 30.2.3.1 and 30.2.3.2
N
Test not applicable to conditions as specified
N
30 .2 .3.1
Parts of insulating material supporting connections
carrying a current exceeding 0.2A during normal
operation, and
N
parts of insulatin g mate rial with in a distan ce of
3mm ,
N
havin g a glo w-w ir e fla mm ability ind ex of at least
850°C according to IEC 60695-2-12
N
30 .2 .3.2
Parts of insulating material supporting
current-carrying connections, and
N
parts of insulatin g mate rial with in a distan ce of
3mm ,
N
subjected to glow-wire test of IEC 60695-2-11
P
Test not carried out on material h aving a glow-wire
ignition temperature according to IEC 60695-2-13
as specified
N