Technical data
LVD TEST REPORT
Report Numbe r : KSQ-LVD 081010
Clause Requirement - Te st Result - Remark Verdict
Page 38 / 63
For pollution degree 1, creepage distance not less
than the minimum specified for the clearance in
table 16, if the clearance has been checked
according to the test of clause 14
Pollu tion degree2
P
29 .2 .2
Creepage distances of supplementary insulation at
leas t as spe cified for basic insu latio n in tab le 17
N
29 .2 .3
Creepage distances of reinforced insulation at least
double as specified for basic insulation in table 17
P
29 .2 .4
Creepage distances of functional insulation not less
than specified in table 18
P
Creepage distances may be reduced if the
appliance complies with clause 19 with the
functional insulation short-circuited
N
29.3
Solid insulation having a minimum thickness of
1mm for supplementary insulation,
N
and 2mm for reinforced insulation
P
This requirement does not apply if the
supplementary insulation, other than mica or similar
scaly material, consists of at least two layers, each
of the layers withstands the electric strength test of
16.3
P
This requirement does not apply if the reinforced
insula tio n , other than mica or similar scaly mate ria l,
consists of at least three layers, any two layers
together withstand the electric strength test of 16.3
P
This requirement also does not apply to
inaccessible insulation and does not exceed the
maximum permissible temperature values, or
P
if the insulation, after conditioning as specified,
withs ta n d s the elec tric stren g th test of 16 .3
N
30 RESISTANCE TO HEAT AND FIRE
30.1
External parts of non-metallic material,
P
parts supporting live parts, and
N
thermoplastic material providing supplementary or
reinfo rc ed insula tion ,
N
sufficiently resistant to heat
P
Ba ll-pres su re test acc ord in g to IEC 6069 5 -10 -2
Non connector N