LVD TEST REPORT
Report Numbe r : KSQ-LVD 081010
Clause Requirement - Te st Result - Remark Verdict
Page 33 / 63
26.9
Terminals of the pillar type constructed and located
as specified
No pillar type N
26.10
Terminals with screw clamping and screwless
terminals not used for flat twin tinsel cords, unless
con du cto rs end s fitted with a device suitable for
screw terminals
N
Pu ll test of 5 N to the con n ec tio n N
26.11
For type Y and Z attachment: soldered, welded,
crimped and similar connections may be used
P
For Class II appliances: the conductor so positioned
or fixed that reliance is not placed on soldering,
w eldin g or crimping alone
P
For Class II appliances: soldering, welding or
crimping alone used, barriers provided, clearances
and creepage distances satisfactory if the
conductor becomes free
P
27 PR OVIS ION FO R EAR T H ING
27.1
Accessible metal parts of Class 0I and I appliances,
permanently and reliably connected to an earthing
terminal or contact of the appliance inlet
Class II appliance N
Earthing terminals not connected to neutral terminal See above N
Class 0, II and III ap pliance have no provision for
earthing
N
Safety extra-low voltage circuits not earthed, unless
protective extra-low voltage circuits
N
27.2
Clamping mea ns adequately secured against
accidental loosening
No clamping means N
Terminals used for the connection of external
equipotential bonding conductors allow connection
of conductors of 2.5 to 6 mm ², and
No equipotential bonding
conductors
N
do not provide earthing continuity between different
parts of the appliance
N
Conductors cannot be loosened without the aid of a
tool
N
27.3
For appliances with supply cord, current-carrying
conductors become taut before earthing conductor,
if the cord slips out of the cord anchorage
No supply cord N
27.4
No risk of corro sio n resulting from con ta ct be tw ee n
metal of earthing terminal and other metal
No risk og corrosion P