Technical data

LVD TEST REPORT
Report Numbe r : KSQ-LVD 081010
Clause Requirement - Te st Result - Remark Verdict
Page 31 / 63
25.22 Appliance inlet: N
- live parts not accessible during insertion or
rem o v al
Y attachm e nts N
- connector can be inserted without difficulty
See above N
- the appliance is not supported by the connector N
- is not for cold conditions if temp. rise of external
metal parts exceeds 75 K, unless the supply cord is
not likely to touch such metal parts
N
25.23
Interconnection cords comply with the requirements
for the supply cord, except as specified
No intercon nec tion cords N
If necessary, electric strength test of 16.3 See above N
25.24
Interconnection cords not detachable without the
aid of a tool if compliance with the standard is
impaired when they are disconnected
N
25.25
Dimensions of pins compatible with the dimensions
of the relevant socket-outlet. Dimensions of pins
and engagement face in accordance with the
relevant plug in IEC 60083
No socke t-outlet N
26 TERMINALS FOR EXTERNAL CONDUCTORS
26.1
Appliances provided with terminals or equally
effective devices for connection of external
cond u ctors
P
Terminals only accessible after removal of a
non-detachable cover
P
26.2
Appliances with type X attachment and appliances
for connection to fixed wiring provided with
terminals in which connections are made by means
of screws, nuts or similar devices, unless the
connections are soldered
Y attachm e nts N
Screws and nuts serve only to clamp supply
cond u ctors, excep t
N
internal conductors, if so arranged that they are
unlikely to be displaced when fitting the supply
cond u ctors
N
If soldered connections used, the conductor so
positioned or fixed that reliance is not placed on
solde r ing alo ne
N
Soldering alone used, barriers provided, clearances
and creepage distances satisfactory if the
conductor becomes free at the soldered joint
N