Technical data

LVD TEST REPORT
Report Numbe r : KSQ-LVD 081010
Clause Requirement - Te st Result - Remark Verdict
Page 30 / 63
- the cord is not clamped by a metal screw which
bears directly on the cord
N
- at least one part of the cord anchorage securely
fixed to the appliance, unless part of a specially
prepared cord
N
- screws which have to be operated when replacing
the cord do not fix any other component, if
applicable
N
- if labyrinths can be bypassed the test of 25.15 is
nevertheless withstood
N
- for Class 0, 0I and I appliances: they are of
insulating material or are provided with an insulating
lining, unless a failure of the insulation of the cord
does not make accessible metal parts live
N
- for Class II appliances: they are of insulating
material, or if of metal, they are insulated from
accessible metal parts by supplementary insulation
N
25.17
Adequate cord anchorages for type Y and Z
attac h m e n t
Power code type is "X" P
25.18
Cord anchorages only accessible with the aid of a
tool, or
P
so constructed that the cord can only be fitted with
theaidofatool
P
25.19
Type X attachment, glands not used as cord
anchorage in portable appliances
Y attachm e nts N
Tyingthecordintoaknotortyingthecordwithstring
not used
N
25.20
Conductors of the supply cord for type Y and Z
attachment adequately additionally insulated
P
25.21
Space for supply cord for type X attachment or for
connection of fixed wiring constructed to permit
che cking of condu cto rs with respe ct to correct
positioning and connection before fitting any cover,
no risk of damage to the conductors when fitting the
cover, no contact with accessible metal parts if a
conductor becomes loose, etc.
Y attachm e nts N
For portable appliances, the uninsulated end of a
conductor prevented from any contact with
accessible metal parts, unless the end of the cord is
such that the conductors are unlikely to slip free
See above N