Technical data

LVD TEST REPORT
Report Numbe r : KSQ-LVD 081010
Clause Requirement - Te st Result - Remark Verdict
Page 29 / 63
25.14
Supply cords adequately protected against
exce ssive flexing
No t mov ed while in operation N
Flexing test:
N
- applied force (N)...................................................:
See above N
- num b e r of flexin g s............................................... : N
The test does not result in:
- short circuit between the conductors N
- breakage of more than 10% of the strands of any
cond u ctor
N
- separation of the conductor from its terminal N
- loosening of any cord guard N
- damage, within the meaning of the standard, to the
cord or the cord guard
N
- broken strands piercing the insulation and
becoming accessible
N
25.15
Conductors of the supply cord relieved from strain,
twisting and abrasion by use of cord anchorage
P
The cord cannot be pushed into the appliance to
such an extent that the cord or internal parts of the
appliance can be damaged
P
Pull and torque test of supply cord, values shown in
table 10: pull (N); torque (not on automatic cord reel)
(Nm).......................................................................:
Pull:3 0 N
Torque:0.1Nm
P
Max. 2 mm displacement of the cord, and
conductors not moved more than 1 mm in the
term in a ls
P
Creepage distances and clearances not reduced
below values specified in 29.1
P
25.16
Cord anchorages for type X attachments constructed and located so that:
N
- replacement of the cord is easily possible
N
- it is clear how the relief from strain and the
prevention of twisting are obtained
N
- they are suitable for different types of cord
N
- cord cannot touch the clamping screws of cord
anchorage if these screws are accessible, unless
separated from accessible metal parts by
supplementary insulation
N