Technical data
LVD TEST REPORT
Report Numbe r : KSQ-LVD 081010
Clause Requirement - Te st Result - Remark Verdict
Page 28 / 63
- flat twin tinsel cord (60227 IEC 41) N
- light polyvinyl chloride sheathed cord (60227 IEC
52), appliance not exceeding 3 kg
N
- ordinary polyvinyl chloride sheathed cord (60227
IEC 53), appliance exceeding 3 kg
P
Supply cords of appliance intended for outdoor use
and appliance having a lamp emitting ultra-violet
radiation are polychloroprene sheathed and not
lighter than ordinary polychloroprene sheathed cord
(60245 IEC 57)
N
Temperature rise of external metal parts exceeding
75 K, PVC cord not used, unless
N
appliance so constructed that the supply cord is not
likely to touch external metal parts in normal use, or
N
the supply cord is appropriate for higher
temperatures, type Y or type Z attachment used
N
25.8
Nom inal cross-sectional area of supply cords
acco rd ing to tab le 11; rated curren t (A);
cross -s ec tion a l area (mm ²).....................................:
Ra ted current:0.5A
Cross-sec tiona l area:1mm
2
N
25.9
Supply cord not in contact with sharp points or
edges
P
25.10
Green/yellow core for ea rthing purposes in Class I
appliance
Class II appliance N
25.11
Conductors of supply cords not consolidated by
lead-tin soldering where they are subject to contact
pressure, unless
P
clamping means so constructed that there is no risk
of bad contacts due to cold flow of the solder
N
25.12
Moulding the cord to part of the enclosure does not
damage the insulation of the supply cord
N
25.13
Inlet opening so shaped as to prevent damage to
the supply cord
No Inlet system n
Unless the enclosure at the inlet opening is of
insulation material, a non-detachable lining or
bushing complying with 29.3 for supp lementary
insulation provided
N
If unsheathed supply cord, a similar additional
bushing or lining is required, unless
N
the appliance is class 0
N