Technical data
LVD TEST REPORT
Report Numbe r : KSQ-LVD 081010
Clause Requirement - Te st Result - Remark Verdict
Page 27 / 63
25.2
Appliance not provided with more than one means
of connection to the supply mains
P
S tationary ap plian ce for m ultiple su pply ma y be
provided with more than one means of connection,
provided electric strength test of 1250 V for 1 min
between each means of connection causes no
breakdown
Single -pha se appliance N
25.3
Connection of supply conductors for appliance
intended to be permanently connected to fixed
wiring possible after the appliance has been fixed to
its support
Not intended to be permanently
connected to fixed wiring
N
Appliance provided with a set of terminals for the
connection of cables or fixed wiring, cross-sectional
areas specified in 26.6
See above N
Appliance provided with a set of terminals allowing
the connection of a flexible cord
N
Appliance provided with a set of supply leads
accommod ated in a suitable compartment
N
Appliance provided with a set of terminals and cable
entries, conduit entries, knock-outs or glands,
allowing connection of appropriate type of cable or
conduit
N
25.4
Cable and conduit entries, rated current of
appliance not exceeding 16 A, dimensions
accordingtotable10
Not intended to be permanently
connected to fixed wiring
N
Introduction of conduit or cable does not reduce
clearances or creepage distances below values
specif ied in 29
See above N
25.5 Method for assemble supply cord with the appliance:
- type X attachm e nt N
- type Y attachm e nt Non-detachable power cord used P
- type Z attachment, if allowed in part 2
N
Type X attachment, other than those with a specially
prepared cord, not used for flat twin tinsel cords
N
25.6 Plugs fitted with only one flexible cord P
25.7
Supply cord not lighter than:
P
- braided cord (60245 IEC 51)
N
- ordinary tough rubber sheathed cord (60245 IEC
53)
N