Technical data
LVD TEST REPORT
Report Numbe r : KSQ-LVD 081010
Clause Requirement - Te st Result - Remark Verdict
Page 25 / 63
24 .1 .1
Capacitors likely to be permanen tly subjected to the
supply voltage and used for radio interference
suppression or for voltage dividing, complying with
IEC 60384-14, or
No capac itors N
tested according to annex F
N
24 .1 .2
Safety isolating transformers complying with IEC
61558-2-6, or
No safety isolating transform ers N
tested according to annex G
N
24 .1 .3
Switches complying with IEC 61058-1, the number
of cycles of operation being at least 10 000, or
No switch es N
Interlock switches are operated 1000 times N
tested according to annex H
N
24 .1 .4
Automatic controls complying with IEC 60730-1 with relevant part 2. The number of
cycles of operation being:
N
- thermostats: 10 000 N
- temperature limiters: 1 000
N
- self-resetting thermal cut-outs: 300
P
- non-self-resetting thermal cut-outs: 30
N
-timers: 3000 N
- energy regulators: 10 000 N
24 .1 .5 A ppliance couplers complying with IEC 60320-1 N o appliance couplers N
However, appliances classified higher than IPX0,
the appliance couplers complying with IEC
60320-2-3
N
24 .1 .6
Small lamp holders similar to E10 lampholders
complying with IEC 60238, the requirements for
E10 lampho lders being applicable
No lamp holders N
24.2
No switches or au tomatic controls in flexible cords
No switch es or autom a tic
controls
P
No devices causing the prote ctive device in the
fixedwiringtooperateintheeventofafaultinthe
appliance
No such devices P
No thermal cut-outs that can be reset by soldering
No such therm al cut-outs N
Appliances for indoor use only may be fitted with
switch e s in flexible cords
N