Technical data
LVD TEST REPORT
Report Numbe r : KSQ-LVD 081010
Clause Requirement - Te st Result - Remark Verdict
Page 24 / 63
Adequate insulating lining provided inside a coiled
spring, the turns of which touch one another
N
No damage after 10 000 flexings for conductors
flexed during normal use or 100 flexings for
conductors flexed during user maintenance
N
Electric strength test, 1000 V between live parts and
acce ssib le me tal parts
N
23.4
Bare internal wiring sufficiently rigid and fixed
No bare internal wiring N
23.5
The insulation of internal wiring withstanding the
electrical stress likely to occur in normal use
N
No breakdown when a voltage of 2000 V is applied
for 15 min between the conductor and metal foil
wrapped around the insulation
N
For circuits having a voltage over 1000 V no
flashover or breakdown occurs; test voltage (V)
N
23.6
Sleeving used as supplementary insulation on
int ernal wir ing retained in position by positive
means
No sleeving N
23.7
The colour combination green/yellow used only for
earthing conductors
Class II appliance N
23.8 Alu minium wires n ot us ed for inte r nal wiri ng P
23.9
No lead-tin soldering of stranded conductors where
they are subject to contact pressure, unless
N
clamping means so constructed that there is no risk
of bad contact due to cold flow of the solder
N
24
COMPONENTS
24.1
Compon ents comply with safety requirements in
relevant IEC standards
P
List of components (see appended table) P
Com ponents not tested and found to comply with
relevant IEC standard for the num ber of cycles
specified are tested in accordance with 24.1.1 to
24.1.6
N
Com ponents not tested and found to comply with
relevant IEC standard, componen ts not marked or
not used in accordance with its marking, tested
under the conditions occurring in the appliance
No such comp one nts N