LVD TEST REPORT
Report Numbe r : KSQ-LVD 081010
Clause Requirement - Te st Result - Remark Verdict
Page 21 / 63
so constructed that they cannot be replaced in an
incorrect position, and so that if they are omitted, the
appliance is rendered inoperable or manifestly
incomple t e
P
22.31
Clearances and creepage distances over
supplementary and reinforced insulation not
reduced below values specified for supplementary
insula tion
N
Creepage distances and clearances over
supplementary or reinforced insulation not reduced
to less than 50% of values specified in 29 if wires,
screws etc. becomes loose
No such wires, screw s N
22.32
Supplementary and reinforced insulation designed
or protected against deposition of dirt or dust
P
Supplementary insulation of natural or synthetic
rubber resistant to ageing, or arranged and
dimensioned so that creepage distances are not
reduced below values specified in 29.2
No such insulation N
Ceramic material not tightly sintered, similar
material or beads alone not used as supplementary
or reinfo rce d insulatio n
No ceram ic ma terial N
Oxygen bom b test at 70 °C for 96 h and 16 h at room
temperature
N
22.33
Conductive liquids that are or may become
accessible in normal use are not in direct contact
with live parts
No conductive liquids N
Electrodes not used for heating liquids N
For class II constructions, conductive liquids that
are or may become accessible in normal use, not in
direct contact with basic or reinforced insulation
N
For class II constructions, conductive liquids which
are in contact with live parts, not in direct contact
w it h reinforced insulation
N
22.34
Shafts of operating knobs, handles, levers etc. not
live, unless the shaft is not accessible when the part
is remove d
No shafts of operating knobs,
handles, levers
N
22.35
Handles, levers and knobs, held or actuated in
normal use, not becoming live in the event of an
insu latio n fault
No such handles, levers and
knobs
N