Technical data

LVD TEST REPORT
Report Numbe r : KSQ-LVD 081010
Clause Requirement - Te st Result - Remark Verdict
Page 20 / 63
22.17
Spacers not removable from the outside by hand or
by means of a screwdriver or a spanner
No spacers N
22.18
Current-carrying parts and other metal parts
resistant to corrosion under normal conditions of
use
P
22.19
D r iv ing be l t s not used as electrical insulation
No driving belts N
22.20
Direct contact between live parts and thermal
insulation effectively prevented, unless material
used is non-corrosive, non-hygroscopic and
non-combustible
No direct contact between live
parts and thermal insulation
N
Comp liance is checked by inspection and, if
necessary, by appropriate test
N
22.21
Wood, cotton, silk, ordinary paper and fibrous or
hygroscopic material not used as insulation, unless
impregnated
No such mate rials used as
insulatio n
N
22.22
Appliances not containing asbestos
No asbestos N
22.23
Oils containing polychlorinated biphenyl (PCB) not
used
No polychlorinated biphenyl N
22.24 Bare heating elements adequately supported No bare heating elements N
In case of rupture, the heating conductor is unlikely
to come in contact with accessible metal parts
N
22.25
Sagging heating conductors cannot come into
contact with accessible metal parts
No saggin g heating condu ctors N
22.26
The insulation between parts operating at safety
extra-low voltage and other live parts complies with
the requirements for double or reinforced insulation
No SELV N
22.27
Parts connected by protective impedance
separated by double or reinforced insulation
No protective impedance N
22.28
Metal parts of Class II appliances conductively
connected to gas pipes or in contact with water:
separated from live parts by double or reinforced
insula tion
Not connected to gas pipes or in
contact with wate r
N
22.29
Class II appliances permanently connected to fixed
wiring so constructed that the required degree of
access to live parts is maintained after installation
Not intended to be permanently
connected to fixed wiring
N
22.30
Parts serving as supplementary or reinforced
insulation fixed so that they cannot be removed
without being seriously damage d, or
P