Technical data

LVD TEST REPORT
Report Numbe r : KSQ-LVD 081010
Clause Requirement - Te st Result - Remark Verdict
Page 18 / 63
- a statement in the instruction sheet that a
disconnection incorporated in the fixed wiring is to
be provided
N
- an appliance inlet N
Singe-pole switches and single-pole protective
devices for the disconnection of heating elements in
single-phase permanently connected class I
appliances, connected in the phase conductor
N
22.3
Appliance provided with pins: no undue strain on
socke t-o utlets
No direct plug-in appliance N
Applied torque not exceeding 0.25 Nm
See above N
Pull force of 50N to each pin after the appliance has
being placed in the heating cabinet; when cooled to
room tempe rature the pins are not displaced by
more than 1mm
N
Each pin subjected to a tork of 0.4Nm; the pins are
not rotating unless rotating does not impair
compliance with the standard
N
22.4
Appliance for heating liquids and appliance causing
undue vibration not provided with pins for insertion
into socke t-o utlets
No heatin g liquids N
22.5
No risk of electric shock when touching the pins of
the plug
0V after 1s P
22.6
Electrical insulation not affected by condensing
water or leaking liquid
No water N
Electrical insulation of C lass II appliances not
affected in case of a hose rupture or seal leak
N
Drain hole is at least 5 mm in diameter or 20 mm
in area with a width of at least 3 mm
N
22.7
Adequate safeguards against the risk of excessive
pressure in appliances provided with
steam-producing devices
No steam-producing devices N
22.8
Electrical connections not subject to pulling during
cleaning of compartmen ts to which access can be
gained without the aid of a tool, and that are likely to
be cleaned in normal use
Not such parts N
22.9
Insulation, internal w iring, windings, comm utators
and slip rings not exposed to oil, grease or similar
substances
N