Technical data
LVD TEST REPORT
Report Numbe r : KSQ-LVD 081010
Clause Requirement - Te st Result - Remark Verdict
Page 17 / 63
20.1 Adequate stability Fixed appliances N
Tilting test through an angle of 10° (appliance
placed on an inclined plane/horizontal plane);
appliance does not overturn
N
Tilting test repeated on appliances with heating
elements, angle of inclination increased to 15°
N
Possible heating test in overturned position;
temperature rise does not exceed values shown in
table 9
N
20.2
Moving parts adequately arranged or enclosed as to
provide protection against personal injury
No movin g parts N
Protective enclosures, guards and similar parts are
non-detachable
See above N
Adequate mechanical strength and fixing of
protective enclosures
N
Self-resetting thermal cut-outs and overcurrent
protective devices not causing a hazard, by
unexpected reclosure
No such devices N
Not possible to touch dangerous moving parts with
test probe
No movin g parts N
21 MECHANICAL STRENGTH
Appliance has adequate mechanical strength and is
constructed as to withstand rough handling
Co m p lies P
No damage after three blows applied to various
parts of the enclosure, impact energy 0,5 ± 0,04 J
P
If necessary, supplementary or reinforced insulation
subjected to the electric strength test of 16.3
N
If necessary, repetition of groups of three blows on a
new sample
N
22
CONSTRUCTION
22.1
Appliance marked with the first n umeral of the IP
system, relevant requirements of IEC 60529 are
fu lfi lled
IPX 0 N
22.2
Stationary appliance: m eans to provide all-pole disconnection from the supply
provided, the following means being available:
P
- a supply cord fitted with a plug
Co m p lies P
- a sw it c h co mplying with 24 . 3 N