LVD TEST REPORT
Report Numbe r : KSQ-LVD 081010
Clause Requirement - Te st Result - Remark Verdict
Page 13 / 63
Protective impedance disconnected from live parts
before carrying out the tests
No protective impedance N
16.2
Single-phase appliances: test voltage 1.06 times
rated voltag e ...........................................................:
220V x 1.06 = 233.2V P
Three-phase appliances: test voltage 1.06 times
rated vo ltag e divided by 3......................................:
N
Leakage current measurements (see appended table) N
16.3 Electric strength tests according to table 7 (see appended table) P
17
OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED
CIRCUITS
No excessive temperatures in transformer or
associated circuits in event of short-circuits likely to
occur in normal use
(see appended table)
P
A pplia nce sup plied with 1.06 or 0.94 times rat ed
voltage and the most unfavourable short-circuit or
ove rloa d likely to occur in norm a l use ap p lied.........:
220V x 1.06 = 233.2V P
Temperature rise of insulation of the conductors of
safety extra-low voltage circuits not exceeding the
relevantvaluespecifiedintable3bymorethan15K
N
Temperature of the winding not exceeding the value
specified in table 8,
P
however limits do not apply to fail-safe transformers
complying with sub-clause 15.5 of IEC 61558-1
N
18
ENDURANCE
N
Requirem ents and tests are specified in part 2 when
necessary
N
19
ABNORMAL OPERATION
19.1
The risk of fire or mechanical damage under
abnormal or careless operation obviated
P
Electronic circuits so designed and applied that a
fault w ill not render the appliance unsafe
No risk of fire or mechan ical
damage
P
19.2
Test of appliance with heating elements with
restricted heat dissipation; test voltage (V): power
inpu t of 0.85 times rate d pow er input......................:
P
19.3
Test of 19.2 repeated; test voltage (V): pow er input
of 1.2 4 times rated pow e r inpu t...............................:
P