Technical data

LVD TEST REPORT
Report Numbe r : KSQ-LVD 081010
Clause Requirement - Te st Result - Remark Verdict
Page 12 / 63
Appliances normally fixed to a wall and appliances
with pins for insertion into socket-outlets are
mounted on a wooden board
N
For IPX3 appliances, the base of w all mounted
appliances is placed at the same level as the pivot
axis of the oscillating tube
N
For IPX4 appliances, the horizontal centre line of
the appliance is aligned with the pivot axis of the
oscillating tube
N
However, for appliances normally used on the floor
or table, the movement is limited to two times 90° for
a period of 5 min, the support being placed at the
level of the pivot axis of the oscillating tube
N
Wall-mounted appliances, take into account the
distance to the floor stated in the instructions
N
Ap p lian ce s with type X atta ch ment fitted with a
flexible cord as described
N
Detachable parts tested as specified
N
15.2
Spillage of liquid does not affect the electrical
insula tion
No spillage of liquid in normal
use
N
Ap p lian ce s with type X atta ch ment fitted with a
flexible cord as described
See above N
Appliances incorporating an appliance inlet tested
with or without an connector, whichever is most
unfavourable
N
De ta ch a b le parts remo v ed N
Overfilling test with additional amount of water, over
a period of 1 m in (l)...............................:
N
The appliance withstands the electric strength test
of 16.3
N
No trace of water on insulation that can result in a
reduction of clearances and creepage distances
below values specified in clause 29
N
15.3
Appliances proof against humid conditions
P
H umidity tes t for 48 h in a hu midit y ca bine t 93% , 30 P
The appliance withstands the tests of clause 16 Complied P
16 LEAKAGE CURRENT AND ELECTRIC STRENGTH
16.1
Leakage current not excessive and electric strength
adequate
P