LVD TEST REPORT
Report Numbe r : KSQ-LVD 081010
Clause Requirement - Te st Result - Remark Verdict
Page 11 / 63
Motor-operated appliances and combined
app lian c es supplie d at 1.06 times rated voltag e .....:
N
Protective impedance and radio interference filters
disconnected before carrying out the tests
No protective impedance and
radio interference filters
N
13.2
Leakage current measured by means of the circuit
described in figure 4 of IEC 60990
N
Leakage current measurements (see appended table) P
13.3 Electric strength tests according to table 4 (see appended table) P
No breakdown during the tests P
14
TRANSIENT OVERVOLTAGES
Appliances withstand the transient overvoltages to
which they may be subjected
See below N
Clearances having a value less than specified in
table 16 subjected to an impu lse voltage test, the
test voltage specified in table 6
Clearances having a value more
than specified in table 16
N
No flashover during the test, unless of functional
insula tion
N
In case of flashover of functional insulation, the
appliance complies with clause 19 with the
clearance short circuited
N
15 MOISTURE RESISTANCE
15.1
Enclosure provides the degree of moisture
protection according to classification of the
appliance
IPX 0 N
Com pliance checked as specified in 15.1.1, taking
into account 15.1.2, followed by the electric strength
test of 16.3
N
No trace of water on insulation which can result in a
reduction of clearances and creepage distances
below values specified in clause 29
N
15 .1 .1
Appliances, other than IPX0, subjected to tests as
spe cifie d in IEC 60 5 29.............................................:
IPX 0 N
15 .1 .2
Hand-held appliance turned continuously through
the most unfavourable positions during the test
No hand-held appliances N
Built-in appliances installed according to the
instructions
No built-in appian ces N
Appliances placed or used on the floor or table
placed on a horizontal unperforated support
See above N