Technical data

LVD TEST REPORT
Report Numbe r : KSQ-LVD 081010
Clause Requirement - Te st Result - Remark Verdict
Page 10 / 63
10 POWER INPUT AND CURRENT
10.1
Power input at normal operating temperature, rated
voltage and normal operation not deviating from
rated power input by more than shown in table 1
(see appended table)
P
10.2
Current at normal operating temperature, rated
voltage and normal operation not deviating from
rated current by more than shown in table 2
(see appended table)
N
11
HEATING
11.1
No excessive temperatures in normal use
Ma rked with hot surface
warning marking or symbol.
P
11.2 Placing and mounting of appliance as described P
11.3
Temperature rises, other than of windings,
determined by thermocouples
P
Temperature rises of windings determined by
resistance method, unless
N
the win d ing s make s it difficult to ma ke the
necessary connections
N
11.4
Heating appliances operated under normal
operation at 1.15 tim e s rate d power input................:
N
11.5
Motor-operated appliances operated under normal
operation at most unfavourable voltage between
0.94 an d 1.06 times rated voltage...........................:
N
11.6
Combined appliances operated under normal
operation at most unfavourable voltage between
0.94 an d 1.06 times rated voltage...........................:
N
11.7
Operation duration corresponding to the most
unfavourable conditions of normal use
P
Appliances are operated until steady conditions are
established
P
11.8
Temperature rises not exceeding values in table 3 (see appended tables)
N
The temperature rise of surfaces likely to collect
dust or insects shall not exceed 60 K
N
Protective devices do not operate
P
Sealing compound does not flow out
No sealing compound N
13
LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING
TEMPERATURE
13.1
Leakage current not excessive and electric strength
adequate
Co m p lies P
Heating appliances operated at 1.15 times rated
power inpu t..............................................................:
N