Specifications

88
SPECIAL FUNCTIONS
CLEARING/PROGRAMMING PATS 1 & 2 SYSTEM (DIESEL)
6
CLEAR PATS 2 SYSTEM
ALL KEYS CLEARED
KEYS PROGRAMMED : 1
PRESS ENTER KEY
PROGRAM KEYS
3 KEYS REQUIRED
PRESS ENTER KEY
After Clearing the PATS module, the
AD100 will automatically switch over to
clearing the DSM (Diesel Smart Mod-
ule) which takes 15 minutes.
NOTE : If CONDITIONS INCORRECT are
displayed then check the connection to
the diesel pump, and clean the connec-
tions.
NOTE : If the time continues after 15
minutes and does not clear, then check
to ensure the system selected is cor-
rect.
NOTE : If WAITING TO CLEAR is not
displayed this indicates the incorrect
system has been selected.
If successful the AD100 will display all
keys cleared and how many keys are
programmed.
The key in the ignition is now pro-
grammed as the master key.
After Master key has been programmed
additional keys can be added in the
normal manual procedure as described
in the previous section