User's Manual

R&D / Automotive Electronics
Title Remote Keyless Entry System Specification Spec. No. DPE-AE-RK019912S
Written by Ban Dong Hoon
Rev. No.
A0
Date 10
th
. Nov. 2003 Page
18 / 25
- Max. Low Output Level : 1V to GND
- Max. Output Current : 500mA
- Fault Diagnostic Request : No
- State During Reset : Off
- Short Circuit Protection Request : Yes
- Over Current Protection Request : Yes
5.1.2.5 2 STEP UNLOCK (A16, PROVISION)
- Type : Low Side Drive
- Max. Low Output Level : 1V to GND
- Max. Output Current : 500mA
- Fault Diagnostic Request : No
- State During Reset : Off
- Short Circuit Protection Request : Yes
- Over Current Protection Req’d : Yes
5.1.2.6 SIREN(A1)
- Type : Low Side Drive
- Max. Low Output Level : 1V to GND
- Max. Output Current : 500mA
- Fault Diagnostic Request : No
- State During Reset : Off
- Short Circuit Protection Request : No
- Over Current Protection Request : No
5.1.2.7 TRUNK RELEASE(A14)
- Type : Normal Open Relay
- Output Level : Battery Voltage to GND
- Max. Switching Current : 60 A
- Max. Continuous current : 10 A @ +23
- Fault Diagnostic Request : No
- State During Reset : Off
- Short Circuit Protection Request : No
- Over Current Protection Request : No
5.1.3 ELECTRIC INPUT