the brush spring, and then remove the brush.
Measure the brush length. Replace the brush if it is
worn beyond the service limit.
SERVICE LIMIT: 6.5 MM
NOTE
If replacement, replace with a brush holder set.
Check the commutator for
- Damage or abnormal wear.
Replace with a
new one.
- Discoloration of the commuttor bar.
Replace
with a ne one.
- Metalic debris between commutator bars
Clean it off
For continuity between pairs of commutator bars.
- Make a continuity check between individual
commutator bars and the armature shaft.
- There should be no continuity.
Check the needle bearing and oil seal.
- Do not rotate smoothly.
Replace with a new
one.
- Damage oil seal.
Replace with a new one.