Specifications

CHARGING SYSTEM
Measure battery current leakage.
Inspect the body of the register/rectifier.
Faulty battery.
Wire harness is short-circuited.
Coupeler is connected incorrectly.
·Short-circuited harness.
·Damaged main switch.
·Register/rectifier is switch.
Check the A.C generator charging coil.
Damaged register/rectifier.
Faulty battery.
Check charge level.
Check the voltage of the register/rectifier
battery line and ground line.
Check the changing coil with the register
/rectifier coupler charging coil.
Inspect the body of the register/rectifier.
NORMAL
ABNORMAL
ABNORMAL
NORMAL
A.C generator coupler connected incorrectly.
Damaged charging coil.
ABNORMAL
NORMAL
ABNORMAL
ABNORMAL
ABNORMAL
OVER 15V
14~15V
UNDER 14V
NORMAL
NORMAL
CORRECT
TROUBLE SHOOTING
No power(key turned on)
Dead battery
- Low fluid level
- Complete discharged
Disconnected battery cable
Main fuse cut
Faulty ignition switch
Low power(key turned on)
Battery undercharged
- Low fluid level
- Battery discharged
Charging system failure
Loose battery connection
Low power(engine running)
Battery undercharged
Battery is failing
Charging system failure
Intermittent power
Loose battery connection
Loose charging system connection
Loose starting systme connection
Loose connection or short circuit in ignition system
Loose connection or short circuit in lighting system
Charging system failure
Loose, broken or short circuit wire or connection
Faulty regulator rectifier
Faulty A.C. Generator
CHARGING SYSTEM