Ventilation Solutions RANGES • WALL OVENS • COOKTOPS • VENTILATION • MICROWAVES • COFFEE SYSTEM • OUTDOOR GRILLS
Ventilation Facts POLLUTANTS TO REMOVE FROM THE KITCHEN Heat, Odors, Grease, Gases, Steam & Smoke FACTORS THAT NEGATIVELY INFLUENCE VENTILATION Open Windows & Doors, Air Conditioning Vents, Ceiling Fans, Island Cooking GENERAL RULE OF THUMB 100 CFM for every 10,000 BTU (*Increase if duct run is long or complicated) Two Types of Ventilation Power Sources Factors to Consider Width & Depth of Cooking Product Hoods OVERHEAD 1 Powerpacks Over-the-Range Microwaves (OTR) Internal Blowers Capture
Ventilation Facts Hoods: Bottom of hood should be 30"– 36" from the finished counter. PowerPacks (with SS Liner): Bottom of liner should be 36" from the finished counter. OTR (above electric cooking): Top of microwave should be 34" above the finished counter. RECOMMENDED MOUNTING HEIGHTS OTR (above gas cooking): Top of microwave should be 36" above the finished counter.
Pro-Style Hoods 18" Pro-Style Hoods 18" High, 267/8" Deep WIDTHS 30," 36," 42," 48" & 54" FINISHES Stainless Steel available with (4) different trim finishes– Chrome, Black, Brass or Copper INTERNAL POWERED–EHD MODELS 600 CFM - EHD3018 or EHD3618 1200 CFM - EHD4218, EHD4818 or EHD5418 EXTERNAL POWERED–EHDR MODELS (REMOTE BLOWER) EHDR3018 or EHDR3618–use REMP3; ILB8 EHDR4218, EHDR4818 or EHDR5418–use REMP16; ILB10 VENTING Vents out the top (vertically) or back (horizontally) 30" & 36" hoods–8" round (ver
MILLENNIA Hoods 18" MILLENNIA Hoods 18" High, 251/2" Deep WIDTHS 30," 36" & 48" FINISHES Stainless Steel INTERNAL POWERED–MHD MODELS 600 CFM - MHD3018 or MHD3618 1200 CFM - MHD4818 VENTING Vents out the top (vertically) or back (horizontally) 30" & 36" hoods–8" round (vertically) or 3 1/4" x 10" (horizontally) 48" hoods–10" round (vertically) or 3 1/4" x 10" (horizontally) CONTROLS Hood switch will control up to two blowers Additional blowers may require use of ARSC remote switch DUCT COVERS Available i
PowerPacks IVS1 or IVSR1 DIMENSIONS 22 5/8" wide, 12 1/4" deep, 6" high INTERNAL POWERED–IVS1 600 CFM EXTERNAL POWERED–IVSR1 (REMOTE BLOWER) Use REMP3–1000 CFM Use ILB8–600 CFM VENTING Vents out the top (vertically)–8" round CONTROLS Hood switch will control up to two blowers Additional blowers will require use of ARSC switch OPTIONAL STAINLESS STEEL LINERS IHL30 for 30" Decorative Hoods IHL36 for 36" Decorative Hoods IVS2 or IVSR2 DIMENSIONS 34 1/2" wide, 12 1/4" deep, 6" high INTERNAL POWERED–IVS2
Over the Range Microwaves PMOR3021 FINISHES Stainless Steel, Black or White INTERNAL POWERED 300 CFM EXTERNAL POWERED (OPTIONAL REMOTE BLOWER) INSTALLER 600 CFM Use ILB8 (600 CFM) and ARSC remote switch Remove OTR fan blower Recommended if using above ERD30 or EGR30 Pro Range VENTING Vents out the top (vertically) or the back (horizontally) 3 1/4" x 10" rectangle duct SPECIAL NOTES Factory set for NON-VENTED MODE (Recirculating before installation) Must turn motor 1/4 turn to change to VENTED Only "UL"
Downdraft Systems RV SIZES 30," 36" & 46" FINISHES Stainless Steel, Black or White INTERNAL POWERED Use CABP3 blower–600 CFM EXTERNAL POWERED (REMOTE BLOWER) REMP3–1000 CFM, 8" round duct REMP16–1600 CFM, 10" round duct VENTING Three options: right or left sides, or bottom SPECIAL NOTES RV30, 36, 46 designed for SGM304, 364, 365 & 466, PGM365, 304, MET, ETT or CER ERV SIZES 30," 36" & 46" FINISHES Stainless Steel only EXTERNAL POWERED (REMOTE BLOWER) REMP3–1000 CFM, 8" round duct REMP16–1600 CFM, 10" r
Accessories Remote Blower Internal Blower REMP3 (pictured) CABP3 REMP16 APPLICATIONS: Install with RV model downdrafts only APPLICATIONS: Use with EHDR, IVSR, RV, ERV or PRV systems Stainless Steel Liners for PowerPacks SIZES Available in five widths: 30," 36," 42," 48" & 54" IHL30 & IHL36 Use with IVS1 & IVSR1 Stainless Steel Duct Covers SIZES Available in five widths: 30," 36," 42," 48" & 54" All widths available in three heights: 6," 12" & 18 IHL42, IHL48 & IHL54 Use with IVS2 & IVSR2 ATD10
In-Line Blowers ILB 8 POWER 600 CFM VENTING 8" round duct APPLICATIONS SUPPLEMENTAL BLOWER– Use in conjunction with internal or remote blowers. MAKE-UP OR REPLACEMENT AIR SYSTEM– Some local HVAC codes require make-up air if you are using a vent system with 1000 or more CFM. The ILB's are a great source for this. Have your builder contact their HVAC contractor to see if this is required in your area. SPECIAL NOTE ILB8 cannot be used with downdraft ventilation.
Creating the Proper Ventilation System 1 Select Cooking Product COOKING PRODUCT MODEL PRO-HOOD ERD60S ERD48S EHD5418 or EHDR5418 EHD4818 or EHDR4818 EHD4809 or EHDR4809 INTEGRATED VENT SYSTEM OVER THE RANGE (OTR) RAISED VENT SYSTEM 2–IVS1 or 2–IVSR1 Plus a custom Stainless Steel Liner NA ERV30 (one for each oven) (must use remote blower) IVS2 or IVSR2 Plus IHL54 or IHL48 NA NA IVS2 or IVSR2 + IHL42 IVS1 or IVSR1 + IHL36 NA NA IVS1 or IVSR1 + IHL36 IVS1 or IVSR1 + IHL30 PCOR30 or PMOR
Creating the Proper Ventilation System 2 Select Cooking Product COOKING PRODUCT MODEL SGM365 SGM364 PGM365 SGM304 HOOD EHD4209 or EHDR4209 EHD3609 or EHDR3609 INTEGRATED VENT SYSTEM IVS2 or IVSR2 + IHL42 IVS1 or IVSR1 + IHL36 MET304 ETT304 RAISED VENT SYSTEM NA ERV36 or RV36 (with appropriate remote blower) PRV36 (must use remote blower) MHD3609 EHD3609 or EHDR3609 EHD3009 or EHDR3009 IVS1 or IVSR1 + IHL36 or IHL30 MHD3609 or MHD3009 MET365 ETT365 CERB365 OVER THE RANGE (OTR) EHD4209 o
Creating the Proper Ventilation System 3 Build the Ventilation Package 2 STEP: 1 VENT SYSTEMS MODEL INTERNAL POWER EHD3018 EHD4218 EHD4818 EHD5418 EHDR3018 EHDR3618 18" Pro Hood – External EHDR4218 EHDR4818 EHDR5418 EHD3009 EHD3609 EHD4209 9" Pro Hood – Internal EHD4809 EHDR3009 EHDR3609 EHDR4209 9" Pro Hood – External EHDR4809 4 5 6 Determine Duct If Over Max Max Length For Length Incl. Length, Choose 1 Blower Sys. Elbows & Trans.
Creating the Proper Ventilation System 4 Build the Ventilation Package 2 STEP: 1 VENT SYSTEMS MODEL INTERNAL POWER MHD3018 Select Vent System/Model MHD3618 MHD4818 18" Millennia Hood MHD3009 MHD3609 MHD4809 9" Millennia Hood 3 4 5 6 Duct Size Needed Determine Duct If Over Max Max Length For Length Incl. Length, Choose 1 Blower Sys. Elbows & Trans.
Creating the Proper Ventilation System 5 Build the Ventilation Package STEP: 1 VENT SYSTEMS MODEL 2 Select Vent System/Model PowerPacks – Internal IVS1 IVS2 PowerPacks – External REMOTE POWER Included 600 CFM Included 1200 CFM IHL36 or NA IHL30 IHL54, IHL48 NA IHL42 or IHL40 IHL36 or REMP3 IHL30 IHL54, IHL48 REMP16 IHL42 or IHL40 NA IVSR2 NA PMOR30 PCOR30 Select Liner & Transition INTERNAL POWER IVSR1 4 3 Select Blower LINER ILB8 & ARSC Included (if used 300 CFM with ERD30 or EG