Installation Instructions Downdraft Raised Vent Models: ERV36-ER, ERV48-ER These downdraft vents are designed for use with Dacor ® ER36D and ER48D series ranges. Part No. 103106 Rev.
Tested in accordance with the latest edition of ANSI Z 21.1 standard for household gas cooking appliances, ANSI/UL 858 household electrical ranges, CAN/CSA-C22.2 NO. 64 Standard for Household Electric Cooking and Liquid Heating Appliances, and UL 507 electric fans . All specifications subject to change without notice. Dacor assumes no liability for changes to specifications. © 2007 Dacor, all rights reserved.
Table of Contents Before You Begin............................................................... 1 Important Safety Instructions........................................... 1 Important Information About Safety Instructions............... 1 Safety Symbols and Labels.............................................. 1 General Safety Precautions.............................................. 2 Customer Service Information.......................................... 3 If You Need Help..................................
Important Safety Instructions General Safety Precautions To reduce the risk of fire, electric shock, serious injury or death when using your appliance, follow basic safety precautions, including the following: Warning 1. 2. 3. Do not install or operate this unit if it has been damaged, dropped, has damaged electrical wiring or is not working properly. If the product is damaged when received, immediately contact the dealer or builder.
Customer Service Information If You Need Help... Appliance Data Plate If you have questions or problems with installation, contact your Dacor dealer or the Dacor Customer Service Team. When you call, have the model and serial number of the appliance ready. The model and serial number are printed on the appliance data label on the front of the unit. The appliance data label also specifies the power supply requirements.
Installation Specifications warning • • Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. Planning the Installation System Layout • The vent system consists of the raised vent itself and a remote blower. You must install a Dacor model REMP3 or REMP16 remote blower for the raised vent to operate properly. For directions on installing the remote blower, see the REMP3/16 installation instructions.
Installation Specifications • • • • Install the raised vent and range so that they can be removed if service is required. Countertop Height: The raised vent is equipped with adjustable anchor legs to accommodate various cabinet heights. See Product Dimensions. Max: 37 ¼” (946 mm) Plan the installation so that all minimum dimensions are met or exceeded. All contact surfaces between the raised vent and any cabinets or walls must be solid and at right angles.
Installation Specifications Planning the Duct Work warning • To reduce the risk of fire and to properly exhaust air, be sure to duct air outside the house or building. Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces or garages. • Tape all duct joints securely to prevent combustion by-products, smoke or odors from entering the home. Doing so will also improve system efficiency. • Do not exhaust more than one vent into a single duct run.
Installation Specifications Duct Work Design Tips • Wherever possible, reduce the number of transitions and turns to as few sharp angles as possible. Two staggered 45° angles are better than one 90°. Keep turns as far away from the hood exhaust as possible, with as much space between each bend as possible. • For best performance, use round duct instead of rectangular, especially when elbows are required. • If multiple elbows are used, try to keep a minimum of 24” of straight duct between them.
Installation Instructions Installation Preparation 2. Cut and remove the foil material inside the knock-out hole. If you fail to remove the foil, the vent will not work. Verify Package Contents 3.
Installation Instructions 4. If the unit will exhaust air from the back, attach a 3 1/4” X 10 duct to the vent hole created by removing the knock-out on the back of the unit. 5. Loosely attach the anchoring legs to the studs on the left and right sides of the raised vent using the provided hex nuts and washers. Installing the Remote Blower and Ducts 1. Install the remote blower according the remote blower installation instructions. 2.
Installation Instructions Electrical Installation warning ELECTRIC SHOCK HAZARD - Do not connect power to the unit until installation is complete. 1. Run the conduit line used to supply power from the raised vent to the remote blower parallel to the duct work. 2. Make sure the raised vent power plug is disconnected from the electrical outlet. 3. Remove the cover from the raised vent electrical access panel. 4.
Installation Instructions Wires from power conduit.
Installation Instructions Verifying Proper Operation warning • Read the raised vent use and care manual completely before operation. • Install all of the front filters prior to operating the raised vent. Refer to the use and care manual for filter installation instructions. caution To prevent damage to the raised vent power cord, route it away from the surfaces of the range before connecting it. 1. Make sure the power switch on the top of the raised vent is in the up position. 2.
Dacor ● 1440 Bridge Gate Drive, Diamond Bar, CA 91765 ● Tel: (800) 793-0093 ● FAX: (626) 403-3130 ● www.Dacor.