Installation Instructions Remote Blowers Models: REMP3, REMP16 Suitable for use in a household cooking area. Suitable for use with solid state controls. To complete this blower, a Dacor ® hood assembly or Dacor downdraft vent must be purchased separately. See the hood or downdraft vent installation instructions to determine suitability. Part No. 65265 Rev.
Table of Contents Important Safety Instructions........................................... 1 Important Information About Safety Instructions............... 1 Safety Symbols and Labels.............................................. 1 General Safety Precautions.............................................. 2 Product Specifications...................................................... 2 Electrical Supply Requirements........................................ 2 Product Dimensions...................................
Important Safety Instructions Important Information About Safety Instructions • The Important Safety Instructions and warnings in these instructions are not meant to cover all possible problems and conditions that can occur. Use common sense and caution when installing, maintaining or operating this or any other appliance. • Always contact the Dacor Customer Service Team about problems and conditions that you don’t understand. See Customer Service Information.
Important Safety Instructions General Safety Precautions To reduce the risk of fire, electric shock, serious injury or death when using this blower, follow basic safety precautions, including the following: warning • • warning Do not install or operate this unit if it has been damaged, dropped, has damaged electrical wiring or is not working properly. If you receive a damaged product, immediately contact the dealer or builder. mum rated input current of the hood or downdraft vent.
Product Specifications Product Dimensions Product tolerances: ±1/16” (±1.6 mm), unless otherwise noted. 19” (48.3 cm) 17 3/8” (44.1 cm) 9 1/2” (24.1 cm) 7 1/2" (19.1 cm) CL Power supply conduit hole CL 7 15/16” (20.2 cm) 5 13/16” (14.8 cm) 3 5/8” (9.2 cm) 9 1/4” (23.5 cm) 8” Nom. (20.3 cm) CL 24 1/4” (61.6 cm) Intake collar 25 1/2” (64.8 cm) Mounting flange Discharge Intake collar Discharge REMP3 26” (66.0 cm) 24 1/4” (61.6 cm) 11 1/2” (29.2 cm) 9 9/16” (24.3 cm) 13 1/8” (33.
Installation Requirements Installation Planning • The base of the remote blower needs to be sealed with mastic or the equivalent to prevent leaks. System Layout A E warning C D To avoid the risk of fire due to the unit overheating: • DO NOT install this blower with a hood or downdraft vent that has an internal blower. • DO NOT install more than one blower to increase the length of the duct run.
Installation Requirements Duct and wiring passing through cutout Wall er w Blo Blower Roof Exhaust, no obstructions within 15” (38 cm) Example of Roof Installation Figure 2 Example of Wall Installation Roof curb Prevailing wind NOTE: Range hood installations with a very short duct run are not recommended due to noise. When a range hood installation can accommodate a short duct run, Dacor instead recommends installation of a range hood with an integral blower instead of using a REMP series blower.
Installation Instructions warning • If the electrical service provided does not meet the power requirements for the hood/downdraft vent and the blower combined, do not continue with the installation. Contact a licensed electrician to correct the situation before continuing. • Failure to connect the wiring as specified may result in an electric shock hazard and/or improper blower operation.
Installation Instructions Electrical Installation 1. Run the wiring used to supply power from the installed downdraft vent or hood to the blower parallel to the duct work. 2. Make sure that power to the downdraft vent or hood is disconnected or turned off at the circuit breaker or fuse box. 3. With the UL certified strain relief attached to the end of the wiring/conduit, feed the wires into the electrical access hole on the under side of the blower and attach it. Roof er w Blo 6.
Technical Data REMP Series Blower Ratings Model Number Nominal Rating* Actual Rating* REMP3 600 CFM 620.5 CFM REMP16 1000 CFM 994.8 CFM * At 0” static pressure REMP16 Blower Performance 5.0 Static pressure - inches of water Static pressure - inches of water REMP3 Blower Performance 4.0 3.0 2.0 1.0 0 100 200 300 400 500 600 Airflow CFM (Cubic feet/minute) 8 700 2.5 2.0 1.5 1.0 0.